GSH900

  Belonging  to

To protect your family

GSH900 - 

V. 1

Household gas  detector

Important: Assembly / maintenance of the appliance must be carried out by qualified personnel and in
accordance with applicable laws and regulations.
The manufacturer assumes no responsibility for the use of products that have to comply with particular
environmental and / or installation standards.

Important note
Before connecting the equipment, it is recommended that you read the instruction manual carefully and
keep it for future reference. It is also recommended to perform the electrical connections correctly as
per enclosed drawings, observing the instructions and the Standards.
N.B. Refer to the documentation in all cases where the symbol is on the side

Channel:  Beinat  gas  solutions

Electric connections also available on

CONFORMITY

Installation and user
guide

EN 50194
EN 50270

CEI 216-8

EN 61010-1

Installation  EN 60079-29-2

Using  the  catalytic  sensor,  the GSH900  detector  detects  the  presence  of  explosive  gas

 

such  as:

Methane and LPG, with trip sensitivity calibrated at 10% of L.E.L.
According  to  the  CEI  216-  8  Norm  of  2005,  the  detectors  are  trigged  by  a  specific  combustible
gas  concentration  in  the  environment.
The  detectors  should  tolerate  common  vapours  and  interfering  substances  usually  present  in
household  environments, and  guarantee  a high  stability with  temperature  and  humidity  variations.

A  series  of  technical  features  make  this  gas  detector  extremely  versatile,  reliable,  accurate,  and
safe.
The  internal  jumper  makes  it  possible  to  select  the  relay  impulse  functioning,  in  order  to  connect
manual  reset  solenoid  valves,  or  the  continuous  functioning,  and  to  activate  N.C.  class  “A”
solenoid  valves  and  sirens.
The  relay,  free  of  voltage,  allows  installation  of  multiple  detectors  on  a  single  solenoid  valve
ensuring  control  of  multiple  dangerous  environments.

The  technical  scheme  is  completed  by  a  circuit  that  controls  the  catalytic  sensor  “efficiency
level”

,

  and  signals  any  possible  fault.

These  technical  features  make  the  detector  ideal  for  civil  environment  safety  according  to
EUROPEAN  REGULATIONS.
GSH900 detector can be mounted on frames supplied for the plates of the following manufacturers:
B-TICINO:  Axolute  series,  LL  series,  Luna  series
VIMAR:  Eixon  series,  Plana  series,  Arke  series,  Idea  series
GEWIS:  Top  System  series

230  VAC

230  VAC

Содержание GSH900

Страница 1: ... E L According to the CEI 216 8 Norm of 2005 the detectors are trigged by a specific combustible gas concentration in the environment The detectors should tolerate common vapours and interfering substances usually present in household environments and guarantee a high stability with temperature and humidity variations A series of technical features make this gas detector extremely versatile reliab...

Страница 2: ...1 W Range of relay contact switching free of voltage 10A 250V resistive Types of gas detected Natural Gas for Natural gas LPG for LPG model Detection sensor Catalytic Alarm sensitivity At 10 of L E L Precision of the detector 1 FS Sensor s faults detected by Fault Circuit Interruption short circuit or wear Test Phase Duration 60 seconds Audible and visual signal alarm by LED diode and buzzer 85 dB...

Страница 3: ...ng installation keeping in mind that the detector should be overhauled after 5 years Components and commands The installation of the detector does not exempt from the compliance with all regulations concerning the characteristics installation and use of gas appliances Particularly the ventilation of the spaces and the elimination of combustion products are described in the UNI norms according to A...

Страница 4: ...s efficiency status and gets it to the functioning temperature This phase lasts about 60 seconds At the end the detector will issue a BEEP Then it is ready for detection Note during the test period the GSH900 does not detect the gas FUNCTIONINGTEST Using a pointed tool or a toothpick press the button under the hole indicated by number 4 see drawing above The ALARM and FAULT LEDs will light up and ...

Страница 5: ...The installation of the detector does not exempt from the compliance with all regulations concerning the characteristics installation and use of gas appliances Particularly the ventilation of the spaces and the elimination of combustion products are described in the UNI norms according to ART 3 LAW 1083 71 and relevant legal provisions 1 Put out all free flames 2 Close the main gas tap or the LPG ...

Страница 6: ...g to Regulations in force An automatic disconnetting switch appropriately identified as the detector sectioning device must be incorporated in the electrical system suitably located and easily accessible N Power supply 230 V AC Ph N C C NO Relay Alarm 1 2 3 4 5 Connection Scheme of GSH900 Detector WARNING All relays are free of voltage Jumper for Relay working Mode 1 With the Jumper opened the rel...

Страница 7: ...ection 230V ac 1 2 3 4 5 1 2 3 4 5 WARNING All relays are free of voltage Connection Scheme with a normally open valve 230VAC Power supply 230 V AC One or more detectors with a normally open valve 230VAC One or more detectors with a normally close valve 230VAC WARNING All relays are free of voltage ...

Страница 8: ...ossible damage direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic e...