Page 3
GSH900
Gas Methane
Test ON Fault Alarm
1
2
3
4
5
replaced by
20014
1) MAINS connected indication LED. After turning on, the GSH900 performs a test of the sensor’s efficiency status,
and gets it to the functioning temperature. This phase lasts about 60 seconds. At the end, the detector will issue a
“BEEP”. Then it is ready for detection.
During the test period, the GSH900 does not detect the gas.
2) FAULT and functional life wear indication LED.
If this LED turns on, it means that the gas detection catalytic sensor is not working efficiently and must be replaced
by an authorized technician.
The sensor duration is guaranteed for 5 years (in clean air).
3) ALARM indication LED. This LED turns on when room gas concentration exceeds the danger level, at 10% of L.E.L.
4) TEST hole. To perform a functioning TEST, insert a pointed tool, like a toothpick.
5
) Label of the gas sensor expiration date.
This label should be applied by the technician during installation
, keeping in mind that the detector should be
overhauled after 5 years.
Components and commands
The installation of the detector does not exempt..... from the compliance with all regulations concerning the characteristics,
installation and use of gas appliances.
Particularly, the ventilation of the spaces and the elimination of combustion products are described in the UNI norms according
to ART. 3 LAW 1083 / 71 and relevant legal provisions.
GSH900 detector must be mounted on frames supplied by BEINAT Srl for the plates of the following
manufacturers:
Frame marked "B1" for B-TICINO, designed for the following Plates: Luna series.
Frame marked "B2" for B-TICINO, designed for the following Plates: Axolute series, LL (Living) series.
Frame marked "B3" for GEWIS, designed for the following Plates: Top System series.
Frame marked "B4" for VIMAR, designed for the following Plates: Eixon series, Plana series, Arke series,
Idea series.
To mount the VIMAR “B4” plates of the EIXON and PLANA series, 4 side hooks must be eliminated, see
drawing below.
Mounting frames supplied
For VIMAR “B4” plates of the EIXON and PLANA series, 4 side hooks must be eliminated