Page  5

- If the device does not start up.
Check that the 230V  power is correctly connected.

- If the fault LED lights up.
If the YELLOW LED is remains ON, check the detection capsule status. It is probably faulty and has to be replaced.
Call an authorized technician..

- If the detector is repeatedly issuing an alarm.
Check that there are no gas leaks.
If the alarm signal and the FAULT indicator light turn on together, proceed as in the previous paragraph.

- If the detector is issuing an alarm and does not shut off the devices connected to it.
Check that the wiring is correct and that the jumper that carries power to the relay has been set properly. All relays
must be free from electrical power.
 Check the drawing of the connections.

If other problems arise, a specialised and/or authorised technician and/or the Distributor of BEINAT S.r.l. should be
contacted  directly.

Before calling a technician

The installation of the detector does not exempt..... from the compliance with all regulations concerning the
characteristics, installation and use of gas appliances.
Particularly, the ventilation of the spaces and the elimination of combustion products are described in the UNI norms
according to ART. 3 LAW 1083 / 71
 and relevant legal provisions.

1) Put out all free flames.
2) Close the main gas tap or the LPG cylinder tap.
3) Do not turn any lights on or off; do not turn on any electrical device or appliance.
4) Open windows and doors in order to increase ventilation.

If the alarm stops, its cause must be found and the relevant consequent measures taken.
If the alarm continues and the cause of gas presence cannot be found or removed, abandon the building and call
the emergency services when outside (fire department, distributors, etc.)

Warning !!

If you have the following symptoms: vomiting, sleepiness, or else, go to the closest first aid station and
inform the operators that you could have been poisoned by Gas Methane or LPG.

WARNING!  Actions  to  be  taken  in  case  of  alarm

4

4

 mm

50 mm

1

2

 mm

4

4

 mm

65mm

Содержание GSH900

Страница 1: ... E L According to the CEI 216 8 Norm of 2005 the detectors are trigged by a specific combustible gas concentration in the environment The detectors should tolerate common vapours and interfering substances usually present in household environments and guarantee a high stability with temperature and humidity variations A series of technical features make this gas detector extremely versatile reliab...

Страница 2: ...1 W Range of relay contact switching free of voltage 10A 250V resistive Types of gas detected Natural Gas for Natural gas LPG for LPG model Detection sensor Catalytic Alarm sensitivity At 10 of L E L Precision of the detector 1 FS Sensor s faults detected by Fault Circuit Interruption short circuit or wear Test Phase Duration 60 seconds Audible and visual signal alarm by LED diode and buzzer 85 dB...

Страница 3: ...ng installation keeping in mind that the detector should be overhauled after 5 years Components and commands The installation of the detector does not exempt from the compliance with all regulations concerning the characteristics installation and use of gas appliances Particularly the ventilation of the spaces and the elimination of combustion products are described in the UNI norms according to A...

Страница 4: ...s efficiency status and gets it to the functioning temperature This phase lasts about 60 seconds At the end the detector will issue a BEEP Then it is ready for detection Note during the test period the GSH900 does not detect the gas FUNCTIONINGTEST Using a pointed tool or a toothpick press the button under the hole indicated by number 4 see drawing above The ALARM and FAULT LEDs will light up and ...

Страница 5: ...The installation of the detector does not exempt from the compliance with all regulations concerning the characteristics installation and use of gas appliances Particularly the ventilation of the spaces and the elimination of combustion products are described in the UNI norms according to ART 3 LAW 1083 71 and relevant legal provisions 1 Put out all free flames 2 Close the main gas tap or the LPG ...

Страница 6: ...g to Regulations in force An automatic disconnetting switch appropriately identified as the detector sectioning device must be incorporated in the electrical system suitably located and easily accessible N Power supply 230 V AC Ph N C C NO Relay Alarm 1 2 3 4 5 Connection Scheme of GSH900 Detector WARNING All relays are free of voltage Jumper for Relay working Mode 1 With the Jumper opened the rel...

Страница 7: ...ection 230V ac 1 2 3 4 5 1 2 3 4 5 WARNING All relays are free of voltage Connection Scheme with a normally open valve 230VAC Power supply 230 V AC One or more detectors with a normally open valve 230VAC One or more detectors with a normally close valve 230VAC WARNING All relays are free of voltage ...

Страница 8: ...ossible damage direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or its packaging to indicates that this product shall not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic e...

Отзывы: