background image

1

forward features 

Maximum forward speed in each E1 link supports up to 1920Kbps 
Maximum forward speed for 4 E1 link supports up to 1920×4=7680Kbps when fully 
loaded 
The forward bit rate is auto allocated, depending on the real-time status of E1 links. 
2

Bandwidth auto-adjustment 

RC902-FE4E1 supports 1~4 E1 links bandwidth auto-adjustment. If any of the E1 
links disconnected, or when it is just back to normal from disconnecting, transmission 
can be automatic achieved trough connecting E1 link and bandwidth can be adjusted 
automatically, but at least 1 E1 link has to connect. 

 
Every E1 link provides 2Mbps bandwidth. If 4 E1 links are working properly, 

8M bandwidth can be provided in total. E1 link “working” means the two converters 
have no alarm occurs in E1 link. 

 

3

Fault Pass Through

 

RC901-FE4E1 provides Fault Pass Through (FPT) for special requirements, e.g. 

which need Spanning Tree, superior switch network management record. The FPT 
defined as: 

If alarm occur on all 4 E1 links, then all the links disconnect, FPT function will 

suspend the UTP port and disconnect the links with Ethernet switches and NIC, until 
any of E1 link no alarm occurred, then system is back to default status. 

FPT set “close” as default status, it is convenient for those customers who have 

no special requirements. Please see the manual about the switch setting of the panel if 
need it. 

 
4. Front panel and LED indicator

   

 
 

Ethernet interface

E1 link 

 

ETH

100M

LNK

ACT

FDX

B

A

C

D

A

B

C

D

 

E1 balanced 

interface 

 

Indicator of 

Ethernet 

Bolt  

 

A

B

C

D    4 E1 links indicator color definitions: 

Green

G

   Normal 

Status

LNK

 

Red

R

   

 

The lost of signal

LOS

 

 

4

Содержание RC902-FE4E1

Страница 1: ...RC902 FE4E1 fast Ethernet to 4 E1converter User guide Beijing Raisecom Science Technology Co ltd...

Страница 2: ...Content Chapter 1 Overview 3 Chapter 2 Connection features 6 Chapter 3 Installation and test 7 Chapter 4 Introduction of DIP Switch 8 Chapter 5 Troubleshooting 12 2...

Страница 3: ...3 Other features Real time BER detecting and E1links auto protection auto reset Resistance for drift of 512UI the ability of counteraction of jitter and drift Selectable BER threshold of link auto res...

Страница 4: ...king means the two converters have no alarm occurs in E1 link 3 Fault Pass Through RC901 FE4E1 provides Fault Pass Through FPT for special requirements e g which need Spanning Tree superior switch net...

Страница 5: ...If A link has been connected A link is green Other link indicators are off Then B link is connected B link is green automatically Green means that normal status And so on A B C D four E1 links are all...

Страница 6: ...Switch and NIC can be connected by both straight line and cross line If UTP port is set to define fixed speed or Full duplex mode RC901 FE4E1 will lose this function The feature of that RC902 FE4E1 co...

Страница 7: ...er to the table and figure below when use the balanced interface 120 PIN No 1 2 3 4 5 6 7 8 Label TD TD Not used Not used RD RD Not used Not used Signification Output Output Input Input 120 balanced i...

Страница 8: ...more than 10 6 4bit choice of compatibility 5bit reserved 6bit configuration of Eth 7bit configuration of Eth Shown as table and figure below 8bit fault pass Disable Enable Remote loopback If any of E...

Страница 9: ...interface Sniffer is for diagnosing Ethernet interface Note Ethernet data also loop back during local loop back it easy to make broadcast storm which occurred in Ethernet switches connected with loca...

Страница 10: ...le auto sensing function force port to 10M half duplex 10M half duplex will be obtained 10M Full duplex port Disable auto sensing function force port to 10M full duplex 10M full duplex will be obtaine...

Страница 11: ...function for special requirements In case of any E1 link was out of work RC901 FE4E1 could transmit the Ethernet packets in the other available E1 links automatically until all E1 links were not avai...

Страница 12: ...rd Please check the fault pass function is Enable or Disable If it is Enable it can make Ethernet port to close 3 E1 line indicator alarm If there is E1 line alarm please find the fault reason accordi...

Отзывы: