Additional Installation Tips

11.3 To Achieve Better EMC Protection

Initially, use the original cabling from Beijer Electronics primarily.

Use shielded cables for RS232 communication.

Use twisted pair and shielded cabling for RS422 and RS485.

Use the cabling intended for the bus type; Ethernet, Profibus, CC-Link,
CAN, Device Net etc.

Install and connect according to applicable specifications for the relevant bus
standard.

Use shielded cabling for Ethernet, preferably with foil + braided shield.

D-sub covers should be shielded, and the shield should be connected to the
cover 360 ° where the cable comes in.

Connect the shield at both ends.

Shielded cable

Not same potential

Ground plane 1

Ground plane 2

Ground plate

Ground plate
in another building

0.1 uF/250 V

5352

With longer distances, there is a risk that the ground potential may be different.
In that case, the shield should only be connected at one end. A good alternative
is to connect the other end of the shield to the ground via a 0.1 uF/250 V plastic
capacitor. Both ends are then connected to the ground in terms of HF, but only
connected to the ground at one end in terms of LF, thus avoiding the 50 Hz
grounding loops.

Metal cabinet

Metal cabinet

Terminal or connector

Terminal or connector

EMC cable gland

Plastic cable gland

Shielded cable

Shielded cable

Short distance

Cable clamp
in steel

5353

1. Use an EMC cable gland or regular plastic cable gland, remove the outer jacket

and connect the shield to the installation plate with a 360 ° metal cable clamp.

2. Place the 24 V DC and communications cabling in one cable trunk/cable duct

and 230/380 V AC in another. If the cables need to be crossed, cross them at
90 ° only. Avoid combining the cabling for stronger 24 V DC outputs with
the communication cabling.

Ferrite cores that are snapped onto the shielded cabling may remove minor
disturbances. Large ferrite pieces that are snapped onto unshielded cabling and
where the wires go 2-4 times around the cores are approximately 5-25 times more
efficient.

Beijer Electronics, MAEN003

34

Содержание iX Panel K100

Страница 1: ...iX PanelK100 Service Maintenance Manual English MAEN003 2010 05...

Страница 2: ...B assumes no responsibility for any errors that may appear in this document Read theentireinstallation manual prior to installing and using this equipment Only quali ed personnel may install operate o...

Страница 3: ...5 2 Keyboard Material 16 5 2 1 Autotex F157 207 16 5 2 2 Screen Surface 17 5 2 3 Auto ex EB 17 6 Hardware Tests 18 7 Additional Hardware 19 7 1 Memory Card 19 7 1 1 Installation 19 7 1 2 Settingsin iX...

Страница 4: ...Cable and Bus Termination RS485 38 12 Fault Tracing 39 13 Software 41 13 1 GeneralInformation aboutSoftware 41 13 1 1 Software Products 41 13 2 Update Software 42 13 2 1 iX Developer 42 13 2 2 Remote...

Страница 5: ...of skincontact wash immediately with plenty ofwater In case of eye contact holdthe eye open ush with plenty of water and get medical attention The gures in this manualserves an illustrative purpose B...

Страница 6: ...y cleaningormaintenance operations disconnect the equipment from the electrical supply Clean the display and surroundingfront cover with asoft cloth and mild detergent Replacingthe battery incorrectly...

Страница 7: ...owto maintain the iXPanel K100 The functions available in iXDeveloperdependonwhich operatorpanel model is used 2 1 iX PanelK100 The followingdrawingsare available foriX Panel K100 Outline drawing Pane...

Страница 8: ...enance personnel are permittedtocarry out the following actions Replacing the Rear Cover Replacing the Display Display Cable Replacing the Complete Front Replacing the Backlight 2 3 Service and Repair...

Страница 9: ...tionabout type number serialnumber environment and an installationdescription The form will be senttothe manufacturer s helpdeskand they will answeryour question or register your improvement fault To...

Страница 10: ...h 9 92 inch 382 mm 100 mm 4 0 inch 15 04 inch 2 28 inch Caution The openings on the enclosure are for airconvection Do not cover these openings 3 2 Installation Process 1 Unpackand check the delivery...

Страница 11: ...e outer sides ofthe holesandcutaccording to the markings 6 5 mm 35 0 mm For text strip 3 5 mm 35 0 mm 1 38 inch 1 38 inch 0 14 inch 0 26 inch 3 Secure the operator panel in position usingallthe fasten...

Страница 12: ...ry before connecting it to the power outlet Ensure that the voltage and polarity of the powersource is correct Use only shielded communication cables Separate high voltage cables from signal and suppl...

Страница 13: ...lp le for the driverin question 3 2 2 Other Connections and Peripherals Cables peripheral equipment and accessories must be suitable forthe application and itsenvironment Forfurtherdetailsor recommend...

Страница 14: ...e and supply voltage Total maximum error 1 min month at 25 C Temperature coefficient 0 034 0 006 ppm C2 Rechargeable battery Power consumption at rated voltage Normal 0 5 A Maximum 1 0 A Display TFT L...

Страница 15: ...ollowing chemicals at room temperature Butanol Nitric acid 3 Hydrochloric acid 5 Nitric acid 10 Isopropyl alcohol Phosphoric acid 43 Na hypochlorite 10 Turpentine Note If exposure to any of the above...

Страница 16: ...ulfuric acid 10 Bleach1 Linseed oil Tomato ketchup Castoroil Methanol Trichloroacetic acid 50 Causticsoda 40 1 Nitric acid 10 White Spirit Cuttingoil Paraffin oil Windex1 Cyclohexanol Persil powderin...

Страница 17: ...3 Autoflex EB It is recommended to use the Auto ex EB keyprotection sheet that can be ordered from BeijerElectronics Solvent Resistance Auto ex EBwithstands exposure to the same chemicalsas Autotex F...

Страница 18: ...panels are designed to ful ll standards such as CE The quality policy and environmentalpolicy place demands on all suppliersandsubcontractors The manufacturerperforms extensive hardware testingbefore...

Страница 19: ...s SiliconDrive SanDisk Industrial Grade Cactus 203 302 and 303 series Other Compact Flash cards may be approved asaccessoriesforthe iXPanelseven if they are not present in the above list due to produc...

Страница 20: ...like to move the les to the internal card select YES tothis question 7 1 2 Settings in iX Developer The size of the internal memory card must be entered in iX Developer 1 Click on Settings onthe Proje...

Страница 21: ...wing functions 1 ON 0 OFF Each letterin MODE has acorrespondingmode switch MODE Description 0000 Run mode boots CE normal operation 0010 System Restore resets the file system and registry reinstalls t...

Страница 22: ...using aballpoint pen 3 Reconnect powerto the operatorpanel 8 2 Cables Most of the operator panels use the same type of ex cable connectors connector flanges Flex cable connector To release the ex cabl...

Страница 23: ...lK100 A torx T10 screwdriver Note Make sure to use adequate ESD protection Follow the steps belowtoreplace the rear cover 1 Power off the operator panel 2 Remove the rear coverofthe operatorpanel by l...

Страница 24: ...wthe instructions underReplacing the Rear Cover toremove the rear cover 3 Disconnect the two excables the ex cable andthe LEDcable fromthe power cardand remove the two plastic nuts thathold the powerc...

Страница 25: ...gplate 8 Re assemble the panel in reverse order 8 4 1 Self test of the Display To perform aself test of the display followthe steps below 1 Start the operator panelin a self test mode see table in the...

Страница 26: ...er Note Make sure to use adequate ESD protection Follow the steps belowtoreplace the complete front ofthe iX Panel K100 1 Power off the operator panel 2 Followthe steps 1 3 and 5 inthe Replacing the D...

Страница 27: ...e iXPanel K100 1 First followthe steps 1 5 insection ReplacingtheRear Cover 2 Gently move the backlight diagonally indirection from the display centerto release the snap in closure that keepsthe backl...

Страница 28: ...40 POWER CONNECTOR 601009011 REAR COVER 601009003 CF COVER 601009001 MOUNTING BRACKETS 601009056 KEY PROTECTION SHEET 601009269 FRONT LABEL 601009137 COMPLETE BOX 601009008 TEST PLUG ETHERNET Ethernet...

Страница 29: ...rom the panel 2 Set the mode switches in mode 1000 Service Menu mode 3 Connect the powersupply 4 Make desired settingsinthe service menu 5 Disconnect the powersupply from the panel 6 Set the mode swit...

Страница 30: ...Menu 9 3 4 Format Memory Card The format memory card function will detect if external andinternal memory cards Select which card toformatand in some cases formattingalternatives Beijer Electronics MAE...

Страница 31: ...off the operator panel 2 Gotothe self test Setthe mode switches tothe self test positions see the table in theMode Switchessection 3 Power on the operator panelandfollow the instructions atthe bottom...

Страница 32: ...hassis and the closest groundingpoint on the door see 3 in drawingabove 3 Connect astrongbut shortgroundingbraid betweenthe doorand the device cabinet see 4 indrawingabove 4 Twist the cables onto the...

Страница 33: ...unithas its shield directly grounded or groundedviaa capacitor Note In many cases connecting the shielded Ethernet cabling to the chassis at both ends is inappropriate Hum or grounding loops canoccur...

Страница 34: ...is to connect the otherend of the shield to the ground via a 0 1 uF 250 V plastic capacitor Both ends are then connected tothe ground in terms ofHF but only connected to the ground at one end in terms...

Страница 35: ...ated average temperature in the cabinet as wellas a large program for controllingthe temperature in the device cabinet An enamel coated steel cabinethasaradiant heatvalue of 5 5 W m2 and degrees C Ins...

Страница 36: ...ELV accordingtoEN 60950 protectionagainst electric shock and UL 950 Example Here is an example that explains why a secure 24 V DC feed can be ruined by mixing 24 V relay contacts with 230 V AC relay c...

Страница 37: ...USB memory stick keyboard or similardevice is plugged in If anumberofunitsare connectedthat have a0 Vand a groundconnection and these are connected to various groundingpoints there is a substantial ri...

Страница 38: ...wires may be onthe same levelor require pull up orpull downtoensure that no faultysignals are detected when the busisin restingmode all transmittersare disconnected 1 2 3 4 5 V 0 V 1 K 1 K 120 ohm 120...

Страница 39: ...ed 4 Checkthe communication ports onthe CPU board The iX Panel K100 is working but the backlight is off 1 Checkthe backlight dimming 2 Checkthat the backlight isconnected to the power card 3 Replace t...

Страница 40: ...l orhorizontalarea acrossthe display It should be atleast2 3 cm wide with agrey orblack color See Replacingthe Display Display Cableforinstructions on how to correct this 2 Make sure the displaycable...

Страница 41: ...3 1 1 Software Products The followingsoftware products are used iX Developer iX Developer isused forcreating application projects for iXPanels and their accessories Remote AccessViewer Remote Access V...

Страница 42: ...ake advantage of new functionality The complete software package consists of the EBOOT the WindowsCE operatingsystem and the system program The upgrade is done by running the Image Loaderexecutable le...

Страница 43: ...ocedure 1 Disconnect the powersupply from the panel 2 Set the mode switches in mode 0100 Image Load mode 3 Reconnect the powersupply 4 Select the operatorpanel to upgrade by enteringitsIP address 5 Cl...

Страница 44: ...n adhesive that is notclassi ed asenvironmentally hazardous Screws may have undergone the followingsurface treatments Bright nickel platingorbright zinc plating The membrane keyboard is made of polyes...

Страница 45: ...label and the plastic bagfor the brackets are recycledas softplastic The manufactureris amemberof the REPAregister The protective lmon the frontisrecycled assoft plastic When the operator panelisnolon...

Страница 46: ...702296600 Tel 18476196068 Fax 46 40 9323 01 Fax 49 7022 9660 103 Fax 1 847 619 6674 info beijerelectronics com info lauer hmi com info usa beijerelectronics com TAIWAN CHINA HitechElectronics Corp Bei...

Отзывы: