14
7.1.3. Controller overview
power
net
current
sensor
menu
language
lamp / current
accessory
cable
60-200
W
max.
1,0
A*
SiC-sensor
SUV13.1A
German
English
Russian
HG 60/4 / 0,67 A
HG 80/4 / 0,80 A
HGA 120/4 / 1,5 A
HGA 200/4 / 2,0 A
type 1 - 60W
type 2 - 80W
type 3 - 120W
type 4 - 200W
Controller technical data:
Mains electricity supply
230 V AC
±
10%
Mains frequency
50 - 60 Hz
Operating frequency
25 - 65 kHz
Efficiency
> 90%
Cos φ
0.96
Pre heating
Yes
Ambient temperatur
0 - 45°C
Case temperature
50°C max.
Fault warning relays
24 VDC/230 VAC, 50mA-5A
Installation
vertikal
Size (H x W x D)
205 x 185 x 80 mm
Cable length net, lamp, sensor
2.5 m
Degree of protection
IP 65
Gewicht
2000 g
UV monitor
The relative UV-intensity is read by a sensor and shown in the display. When dropping
below the minimum alert value (e.g. 50%) „Pre-alarm“ is signalled by a yellow LED and
appropriate relay contact. When the lamp fails “Main-alarm” is signalled by the red LED
and the appropriate relay contact.
Hour counter
Total hours and lamp hours are counted continuously. The internal value will renewed
every hour. The lamp hours are shown on the display and can be reset when the lamp
will be changed.
Menu
You reach the menu by pressing the Enter button 2 seconds. With buttons / you can
browse through the menus up / down. Enter calls up the menu point for changes. Either
the changing will occur immediately or the value will called and can be changed
afterwards. With buttons / you can modify the values. With Enter the adjusted value
will be acknowledged / stored. After 10 seconds waiting an automatically return to the
basic display will take place.