11
5.1.1. Life of the main modules / resources
Equipment
maintenance
Intervals Testing and inspection
Max. Life life
UV lamp
T
8,000 h
8,000 -10 000h
Quartz immersion tube
R, T
8,000 h
48 months *
Gasket Set
P, T
8,000 h
12 months
UV sensor
P, T
P, T
48 months
Electronic Ballast(EVG)
P, T
8,000 h
48 months *
Fuses
P, T
with Maintenance
48 months *
UV reactor
R, K, T
with Maintenance
120 months *
Switchbox
K, P, T
with Maintenance
120 months *
Stainless steel modules
R, K
with maintenance
120 months *
Screw connection
K, T
with Maintenance
24 months *
R = cleaning
T = exchange
K = control
P = Check
* Reusing after examination
Grey marked = wearing parts
6. Design and in conformity to
Low-voltage switchgear unit combination
IEC 61439-1/-2 2011 EN 61439-1/-2 2011 VDE 0660-600 2012
Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU
DIN EN 60335-1:2005-07 safety of electrical installations both in household,
commercial, industrial and water sectors
6.1.1. Interfaces
Switch box / cabinet
terminal strip
fuse
Reactor
flange UV system
Installation site
Indoor frost-free
Maximum humidity 70% at 35 ° C
Ambient temperature max. 35 ° C
water temperature
35° C HG lamps
55° C HGA lamps
Special operating conditions
Accessible to operation and maintenance
Compliance with the line length