31
Peak hold function
(AC-Current)
:
(only
UNITEST Clamp Meter CHB 37
, only manual range selection)
Range
Resolution Accuracy
(50…60 Hz)
Overload protection
400 A
0,1 A
5
(3% rdg +10 Digits)
AC 1100 A
1000 A
1 A
Continuity test:
Range
Resolution
Accuracy
Overload protection
< 40
V
< 0,5 V
600 V rms
Resistance:
Range
Resolution Accuracy
Open circuit voltage
Overload protection
400
V
0,1
V
5
(1,5%rdg+5D)
4 k
V
0,001 k
V
40 k
V
0,01 k
V
5
(1,5% rdg
< 0,5 V DC
600 V rms
400 k
V
0,1 k
V
+ 3 Digits)
4 M
V
0,001 M
V
40 M
V
0,01 M
V
5
(2%rdg+3D)
Peak hold function
(AC-Voltage)
:
(only
UNITEST Clamp Meter CHB 37
, only manual range selection)
Range
Resolution
Accuracy
(50…60 Hz)
Input Impedance
Overload protection
4 V
0,001 V
5
(3 %
app. 11 M
V
40 V
0,01 V
rdg
DC 1100 V
400 V
0,1 V
+ 10 Digits)
app. 10 M
V
AC 800 V
600 V
1 V
Diode test:
Range
Resolution
Accuracy
Overload protection
0,001 V
5
(1,5% rdg + 2 Digits) 600 V rms
Reaction time for peak value: < 100 ms
Warranty
24 months' warranty
UNITEST instrumtens are subject to stringent quality controls. If, in
the course of normal daily use, a fault should occur, we provide 24
months' guarantee (only valid with invoice). Faults in manufacture
and materials will be rectified by us free of charge, provided the
instrument has not been tampered with, and is returned to us
unopened. Damage due to dropping, abuse or misuse is not covered
by the guarantee. Our Service Department will repair any faults that
occur outside the guarantee period. This Instruction Manual has
been prepared with great care. No liability is accepted for the
correctness and completeness of the data, illustrations, and
drawings it contains.
BEHA reserves the right to make changes.
PTDB93470-05.qxd 14.12.2005 9:56 Uhr Seite 31