48
Instructions for the installer (qualified
professional)
Appliances with three-pole cable are set up for operation with
alternating current at the voltage and frequency indicated on the
rating plate. The voltage of the heating elements is 220 - 240 V.
Remember that the connection wire should match the
connection type and the power rating of the cooker. The
connection wire must be secured in a strain-relief clamp. The
ground wire must be connected to the marked clamp of the
terminal. The electric supply of the appliance must be equipped
with an emergency switch with a distance between the contacts
of at least 3 mm which disconnects the entire appliance from the
mains in a case of emergency. Read the information on the rating
label and the connection diagram before connecting the
appliance to the mains.
When the socket is not accessible for the user or a fixed
electrical connection of the appliance is required, an all-pole
disconnecting device must be incorporated during installation.
Disconnecting devices are switches with a contact opening
distance of at least 3 mm. These include LS-switches, fuses and
protectors (EN 30335).
Your domestic circuit must be equipped with an automatic
circuit breaker.
The appliance must be grounded.
Check that the technical data of your energy supply meet the
values on the nameplate.
The power cord must not touch hot areas and its temperature
must not exceed 75
0
C.
Do not bend or compress the power cord.
Check the power cord regularly. The power cord must be
replaced by a qualified professional only!
Connection diagram
Voltage
heating
elements 220 - 240 V.
Any
kind
of
connection: the safety
wire
must
be
connected to the
E-terminal.
Recommended
type
of
connection
lead:
H07RN-
F3G4mm
2
E = ground wire; colour: green / yellow.