background image

  User manual   |   EMS-8x-WC  |   Beckmann GmbH

6 Other

6.1 Operating mode “Lock contact” P37 = OFF

6.2 Operating mode “Doorframe contact” P37 = ON

Page 12

Содержание EMS-8 WC Series

Страница 1: ...oin box EMS 8x WC User manual for Door opener potential free with feedback input for door contact Beckmann GmbH 2016 02 03 2016 Blåbærdalen 30 6518 Kristiansund Tele 91795392 e post post tgelectronics no ...

Страница 2: ...ccident misuse unauthorized changes repair or innovations of the product Furthermore the Beckmann GmbH is not liable for losses costs faults or consequential losses that may emerge by using this product The technical data correspond to the current conditions Misprints errors or changes reserved Beckmann GmbH Brandtstraße 1 33161 Hövelhof Fon 49 0 52 57 98 23 0 Fax 49 0 52 57 98 23 11 info beckmann...

Страница 3: ... 7 4 Operation 8 5 Programming 9 5 1 Procedure 9 5 2 Counter editing 9 5 3 Adjusting operating parameters 9 5 4 Switch parameter 9 5 5 Parameter EMS 8x Door 10 6 Other 12 6 1 Operating mode Lock contact P37 OFF 12 6 2 Operating mode Doorframe contact P37 ON 12 6 3 Switching on 13 6 4 Factory default settings 13 6 5 Software version 13 6 6 Readout serial number 13 Figure 1 Dimensions 5 Page 3 ...

Страница 4: ... device only under faultless conditions as well as due safety and risk conscious regarding the user manual Especially eliminate faults that may impair safety immediately Keep the user manual always on site of the device Pay attention additional to the user manual to the general valid legal and other obligatory rules such as accident prevention and environmental protection Do not make any changes a...

Страница 5: ...in rooms For fixing the device there are three drillings with a diameter of 6 mm at the back side It must be taken care that the case is mounted vertically because otherwise the functioning of the coin selector may be reduced The EMS 8x should be mounted at a solid wall in order to avoid heavy vibrations Page 5 Figure 1 Dimensions ...

Страница 6: ... maintain electrical systems to wire switch and control cabinets to install controlling software to ensure proper functioning of electrical components and to identify possible hazards in the work with electric and electronic systems Since this is a stationary device with a fixed main power supply an RCBO must be installed on the installation side Requirements main power supply is power less RCBO i...

Страница 7: ... 3 3 Maintenance The devices of the EMS 8x series are nearly maintenance free Only the coin selector has to be cleaned sometimes in order to guarantee a proper operation Page 7 Figure 3 Connection of Door Lock Contact and External Access ...

Страница 8: ...osed and a door contact is used the display will show Occ Occupied After opening the door contact the unit is free and the minimum insert is displayed Occ Occupied is also displayed when no amount has been inserted and the door contact is closed If there is no door contact connected the Opn Open message is displayed until the deposited amount for the time has expired Page 8 Display shows minimum i...

Страница 9: ... sections the 3 types of parameters counter operating values and switches are described 5 2 Counter editing Counters are cash counters customer counters or hour meters There are erasable and non eraseable counters The erasable counters can be erased by pressing the or button Some counters have a range higher than 999 As the display has only 3 digits the notation is segmented on values higher than ...

Страница 10: ... not erasable counts as P05 Counter 0 to 49 999 P10 Operating Hours 1 Operation Hours in hours and minutes Counter 0 to 99 999 59 P11 Operating Hours 2 not erasable as P10 Counter 0 to 99 999 59 P20 EMS 81 Minimum Insertion Indicates the amount of coins that has to be inserted at least Operat 1 to 100 EMS 82 Minimum Insertion Indicates the amount of money that has to be inserted at least Operat 0 ...

Страница 11: ...nd P02 Switch On Off P29 Token Value Determines the value of one single token Operat 0 01 to 599 99 P30 Test Mode Test Mode of device can be started Switch Start Stop P31 In Operation If OFF the device can be switched out of service in case of failure Switch On Off P37 Operating mode input contact OFF Lock contact An Doorframe contact Switch On Off P38 Continuous operation The device gives a pulse...

Страница 12: ...User manual EMS 8x WC Beckmann GmbH 6 Other 6 1 Operating mode Lock contact P37 OFF 6 2 Operating mode Doorframe contact P37 ON Page 12 ...

Страница 13: ...appears in the display 6 5 Software version With parameter P99 details about the software version can be read out Press to switch between the subparameters P99 1 to P99 6 P99 1 Software version P99 2 Language coin table 1 German 2 English 3 German_Switzerland 4 Denmark 5 Latvia 6 Norway 7 Czechia P99 3 Feature 1 P99 4 Feature 2 P99 5 Feature 3 P99 6 Feature 4 6 6 Readout serial number For service ...

Страница 14: ... tolerance ranges This is the default factory setting Strict Validation Coins are analyzed in strict tolerance ranges Improved detection of counterfeits The acceptance of the set coin type has been slightly decreasing The lock switch normal must be set to ON Very strict Validation Coins are analyzed in very strict tolerance ranges Improved detection of counterfeit coins The acceptance of the coin ...

Страница 15: ... the circuit board must be identified In version 1 v1 the red socket is located on the left side Please use plug no 1 In version 2 v2 the red socket is located below the three push buttons Please use plug no 2 To start the update the device must be switched on Please wait until the process is complete Page 15 Figure 6 SD card adapter with numbered connectors Figure 7 Identification hardware versio...

Страница 16: ...User manual EMS 8x WC Beckmann GmbH 9 EC Declaration of Conformity Page 16 ...

Страница 17: ...C Max switched power Closer potential free General data Power consumption 3 W Operating temperature 0 to 40 C Operating humidity 30 to 70 Weight 3 5 kg Dimensions W x H x D 162 x 260 x 110 mm Page 17 Blåbærdalen 30 6518 Kristiansund Tele 91795392 e post post tgelectronics no ...

Отзывы: