background image

the Security setting, refer to the help screen in the General Setup menu and to 

Basic instrument

setup

 on page 12.

Start up

Push the 

POWER

 button to turn on or turn off the instrument.

Basic instrument setup

Make sure that the battery is sufficiently charged before use. To charge the battery, refer to 

Charge

the battery

 on page 17.

Refer to the help screen for more information.
To update or change the basic instrument setup:

1.

Push the menu button.

2.

Navigate to Communication Setup.

3.

Push the up or down arrow and navigate to General Setup, then push the Select button.

4.

Update or change the options. Default values appear in parentheses.

Option

Description

Backlight Timeout

5 -300 seconds (30). 0 disables the feature.

Backlight Contrast

(High), Medium, Low

Language

English, Japanese

Security

This feature is checkbox controlled. A change to this setting becomes active when the
user exits the General Setup screen.
If the Security feature is set to on (the box is checked), a user must select the Sign On
icon and put in the current administrator password to get Administrator level access. If
the feature is on but no password is put in, the user has only Operator level access.
If the Security feature is set to off (the box is not checked), a user has both Operator
and Administrator level access.

Change Password

The default password is 123456. If a user forgets the password, technical support can
supply a temporary password. The user must give the instrument serial number and
system date for a temporary password to be generated.

Feedback Volume

(Intermediate). This setting can be adjusted up or down.

System Date

mm/dd/yyyy, dd/mm/yyyy, yyyy/mm/dd

System Time

12 or 24 hour format

Data display setup

Change the settings for how the instrument shows and stores data in the Data Display Setup screen.
Different models of the instrument can have different settings and parameters. Refer to 

HHPC

models

 on page 6.

To update or change a setting:

1.

In the instrument menus, navigate to Sample Setup.

2.

Use the up or down arrow keys to navigate to Data Display Setup, then push the Select button.
The display shows the Data Display Setup screen.

3.

Configure the settings. The Data Display Setup screen includes check-boxes, radio buttons and
drop down menu fields. Refer to the help screen for more information.
The Sample screen changes to agree with the display setup. Characteristics such as font size
may be different for different configurations.

12

   

English

Содержание HHPC2+

Страница 1: ...DOC026 97 80271 HHPC 6 HHPC 3 HHPC 2 10 2013 Edition 7 User Manual Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Страница 2: ...s in a minute USB support Simple data export to memory stick or direct connect to PC via USB cable No software required Ethernet support Access particle data over network with an internet browser such...

Страница 3: ...out limitation direct incidental and consequential damages and disclaims such damages to the full extent permitted under applicable law The user is solely responsible to identify critical application...

Страница 4: ...ions 1 The equipment may not cause harmful interference 2 The equipment must accept any interference received including interference that may cause undesired operation Changes or modifications to this...

Страница 5: ...quality in Clean rooms Manufacturing processes Pharmaceutical production Three models of the instrument are available The main differences are given in Table 1 The cradle keeps the instrument in an u...

Страница 6: ...radle accessory optional 4 AC adapter Data and power connections Figure 2 shows the locations of the data and power connections The ethernet port is available only on the cradle For more information o...

Страница 7: ...h drive or memory device 9 Ethernet port 5 Threaded tripod mount User interface and navigation User interface The LCD display screen and the 7 button keypad on the front of the instrument operate as t...

Страница 8: ...e for some menus Information on the help screens helps the user set up and use the instrument To show the information on a help screen highlight the icon in the lower right corner of the display then...

Страница 9: ...ption 1 Push the Menu button 2 Push the right or left arrow buttons to highlight an icon Push the Up or Down arrow buttons to move through sub menu options 3 Push the Select button to accept the highl...

Страница 10: ...sed vehicle in direct sunlight Failure to obey this precaution can cause the battery to overheat and cause a fire or explosion Note Potential instrument damage Do not use the instrument in locations w...

Страница 11: ...is put in the user has only Operator level access If the Security feature is set to off the box is not checked a user has both Operator and Administrator level access Change Password The default pass...

Страница 12: ...unt process until there are no new counts 4 Remove the zero count filter for normal operation Sample setup Refer to the help screen for more information Change the settings for how the instrument runs...

Страница 13: ...cess The instrument begins the sample process with the default or stored Sample Setup values While the instrument takes samples the display shows the sample status current sample number and the sample...

Страница 14: ...sh the up or down arrows to scroll through the data The data scroll in sequence from the current record The data include the date and time of collection the record number currently in view channels an...

Страница 15: ...he IP address Subnet Mask and Gateway address To do this do one of the following a Put the IP Address Subnet and Gateway data in the appropriate fields OR b Select the DHCP check box If the DHCP box i...

Страница 16: ...C adapter plug to the AC adapter connector of the optional cradle then attach the instrument to the cradle Connect the AC adapter plug to the AC adapter connector on the bottom of the instrument An am...

Страница 17: ...l indicator shows in the display When the warning condition is cleared the indicator goes out of view Table 4 describes the kinds of warnings that can occur Table 4 Warnings Warning Description Laser...

Отзывы: