Commissioning
EL3783
147
Version: 1.1
Index F008 Code word
Index (hex) Name
Meaning
Data type
Flags
Default
F008:0
Code word
reserved
UINT32
RW
0x00000000
(0
dec
)
Index F010 Module list
Index (hex) Name
Meaning
Data type
Flags
Default
F010:0
Module list
Maximum subindex
UINT8
RW
> 10 <
F010:01
SubIndex 001
Analog input profile (300)
UINT32
RW
0x0000012C
(300
dec
)
F010:02
SubIndex 002
Analog input profile (300)
UINT32
RW
0x0000012C
(300
dec
)
F010:03
SubIndex 003
Analog input profile (300)
UINT32
RW
0x0000012C
(300
dec
)
F010:04
SubIndex 004
Analog input profile (300)
UINT32
RW
0x0000012C
(300
dec
)
F010:05
SubIndex 005
Analog input profile (300)
UINT32
RW
0x0000012C
(300
dec
)
F010:06
SubIndex 006
Analog input profile (300)
UINT32
RW
0x0000012C
(300
dec
)
F010:07
SubIndex 007
Analog input profile (300)
UINT32
RW
0x0000012C
(300
dec
)
F010:08
SubIndex 008
Analog input profile (342)
UINT32
RW
0x00000156
(342
dec
)
F010:09
SubIndex 009
Analog input profile (342)
UINT32
RW
0x00000156
(342
dec
)
F010:10
SubIndex 010
Analog input profile (342)
UINT32
RW
0x00000156
(342
dec
)
Index F081 Download revision
Index (hex) Name
Meaning
Data trype
Flags
Default
F008:0
Download revision
reserved
UINT32
RW
0x00000000
(0
dec
)
5.7
Notices on analog specifications
Beckhoff I/O devices (terminals, boxes, modules) with analog inputs are characterized by a number of
technical characteristic data; refer to the technical data in the respective documents.
Some explanations are given below for the correct interpretation of these characteristic data.
5.7.1
Full scale value (FSV)
An I/O device with an analog input measures over a nominal measuring range that is limited by an upper and
a lower limit (initial value and end value); these can usually be taken from the device designation.
The range between the two limits is called the measuring span and corresponds to the equation (end value -
initial value). Analogous to pointing devices this is the measuring scale (see IEC 61131) or also the dynamic
range.
For analog I/O devices from Beckhoff the rule is that the limit with the largest value is chosen as the full scale
value of the respective product (also called the reference value) and is given a positive sign. This applies to
both symmetrical and asymmetrical measuring spans.