background image

Installation Instructions 

 

 

 
 

Connecting devices 

 

Warning

 

 
The power supply plug must be withdrawn! 
 
Please read the documentation for the external devices prior to connecting 
them. 
 
During thunderstorms, plug connector must neither be inserted nor 
removed. 
 
When disconnecting a plug connector, always handle it at the plug. Do not 
pull the cable! 
 

 

Connecting cables 

 

The connections are located behind the outer housing of the Industrial PC 
and are documented in the 

Product Description

 chapter. 

 
When connecting the cables to the Industrial PC, proceed according to the 
following sequence: 

• 

Switch off all the devices that are to be connected. 

• 

Disconnect all the devices that are to be connected from the power 
supply. 

• 

Connect all the cables between the Industrial PC and to the 
devices that are to be connected. 

• 

Connect all data transfer cables (if present) to the appropriate 
plug-in receptacles of the data/telecommunication networks. 

• 

Reconnect all devices to the power supply. 

 

 

Check voltage rating and connect 

 

Fitted with the 24 V

DC

 power supply unit: 

1.  Check that the external power supply is providing the correct 

voltage. 

2.  Insert the power supply cable that you have assembled (see the 

section 

Fitting the cable

) into the Industrial PC's power supply 

socket. Then connect it to your external 24 V power supply. 

 

 

 

Warning

 

 

If a 24 V UPS is installed, the same type of rechargeable battery must 
be used. 

 

 

14

 

 CP71xx 

Содержание CP71 Series

Страница 1: ...Installation and Operating instructions for Panel PC CP71xx Version 1 2 Date 2006 03 06...

Страница 2: ......

Страница 3: ...of the PC 10 Earthing measures 10 Power Supply Connection 11 Electrical data 11 Pin assignment of the connector 11 Fitting the cable 12 Assembling the connector 12 Connecting Power Supply 13 Cable Cro...

Страница 4: ...Table of contents 6 7 Assembly dimensions 20 Appendix 21 Technical data 21 Approvals 21 FCC Federal Communications Commission Radio Frequency Interference Statement 21 FCC Canadian Notice 21 2 CP71xx...

Страница 5: ...et out in 443 of the German Civil Code or a statement about the assumed use according to the contract as set out in 434 para 1 clause 1 no 1 of the German Civil Code In the event that it contains tech...

Страница 6: ...he equipment must first be switched off after which the Industrial PC can be uncoupled from the plant Pulling out the fieldbus connection plug uncouples the PC optional Items of equipment that have be...

Страница 7: ...ional regulations depending on the machine type Depending on the type of machine and plant in which the Industrial PC is being used there will be national regulations for the control of such machines...

Страница 8: ...wo M4 screws 1 using a combination wrench SW 7 and the Allen screw 2 using a No 2 Allen key see photo above The cover of the housing can then be removed to the rear i Note The position of the screws v...

Страница 9: ...shead screw a and removing the sheet metal cover you can pull out the CD ROM drive Unscrewing the crosshead screw b and removing the card holder allows access to the free slot b 3 4 a 5 2 6 1 Access t...

Страница 10: ...interface COM1 4 which is connected to a 9 pin SUB D pin connector DVI I interface in use DVI The DVI I interface 5 is used for connecting the Control Panel USB interface in use USB3 An additional US...

Страница 11: ...n temperature make sure that moisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a de...

Страница 12: ...far as possible Use the position of the screen as a guide for the correct installation height it should be optimally visible for the user at all times The PC should not be exposed to direct sunlight W...

Страница 13: ...rent carrying capacity of the 24 V power supply unit Output voltages from the 24 V power supply unit Current loading maximum 5 V 8 A 5 V 0 5 A 12 V 4 A 12 V 0 5 A 3 3 V 4 A 5 V VSB 0 5 A Pin assignmen...

Страница 14: ...the included material for assembling the connectors Assembling the connector The connector is specified for 16 A and can lift conductive cross sections until 2 5 mm2 Fitting the connector to the cable...

Страница 15: ...ur distribution voltage into account so that is secured that the voltage doesn t fall under 22 V at the power supply Insert Fuse The power supply must be protected with 16 A PC_ON Power Status The cir...

Страница 16: ...evices that are to be connected Disconnect all the devices that are to be connected from the power supply Connect all the cables between the Industrial PC and to the devices that are to be connected C...

Страница 17: ...ausing damage by switching off while the software is running is very high Warning When you have shut down the Industrial PC you have to switch off power supply for at least 10 seconds before rebooting...

Страница 18: ...CD provided on the Industrial PC Driver archive for the Industrie PC C9900 S700 xxxx There you also find the help file TcUpsShellExt chm before the installation of the software Start the driver softwa...

Страница 19: ...to be replaced according to the rules of the board manufacturer Danger Danger of Explosion if battery is incorrectly replaced Replace only with same or equivalent type recommended by the manufacturer...

Страница 20: ...ncorrect Other cause Remove floppy disk or CD and press any key Check the setup settings Call Beckhoff Service Computer boots software starts but control does not operate correctly Cause of the fault...

Страница 21: ...eckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ranging services world wide sup...

Страница 22: ...Dimensions a b t CP7110 10 Display 353 8 308 3 29 5 CP7111 12 Display 353 8 326 3 29 5 CP7112 13 Display 426 395 30 5 CP7113 19 Display 504 455 47 Numerical keyboard Dimensions a b t CP7120 10 Display...

Страница 23: ...during transport and storage as in operation Suitable packaging of the Control Panel can improve the resistance to impact during transport The ambient temperature during storage and transport must be...

Отзывы: