Содержание CP6900-0001-0000

Страница 1: ...Installation and Operating instructions for CP6900 0001 0000 CP6906 0001 0000 Economy built in Control Panel with DVI USB Extended interface Version 1 3 Date 2019 06 05 ...

Страница 2: ......

Страница 3: ...duct overview 7 2 2 Appropriate Use 8 2 3 Access to the connectors 8 2 4 Interfaces 9 2 4 1 Power Supply X101 9 2 4 2 USB out X102 X103 9 2 4 3 USB in X104 9 2 4 4 USB Extended Input X105 10 2 4 5 DVI E Input Digital Visual Interface Extended X106 10 2 4 6 Ground connection 10 2 5 Connection Kits 11 2 5 1 Connection Kits DVI E USB E connection for CP690x optional 11 3 Installation 12 3 1 Transport...

Страница 4: ...7 5 3 Servicing and maintenance 18 5 3 1 Cleaning 18 5 3 2 Maintenance 18 5 4 Emergency procedures 18 5 5 Shutting down 18 5 5 1 Disposal 18 6 Troubleshooting 19 7 Assembly dimensions 20 8 Technical Data 22 9 Appendix 23 9 1 Beckhoff Support and Service 23 9 1 1 Beckhoff branches and partner companies 23 9 1 2 Beckhoff company headquarters 23 9 2 Approvals for USA and Canada 24 9 3 FCC Approvals f...

Страница 5: ...stered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners 1 1 3 Patent Pending The EtherCAT Technology is covered including but not limited to the following patent applications and patents EP1590927 EP1789857 DE102004044764 DE102007017835 with c...

Страница 6: ... injury WARNING If you do not adhere the safety advise adjoining this symbol there is danger to life and health of individuals Hazard to individuals CAUTION If you do not adhere the safety advise adjoining this symbol there is obvious hazard to individuals Hazard to devices and environment Attention If you do not adhere the notice adjoining this symbol there is obvious hazard to materials and envi...

Страница 7: ...of the equipment must first be switched off after which the Control Panel is to be disconnected from the equipment Disconnect the device by unplugging the connectors on the rear side of the Control Panel Items of equipment that have been switched off must be secured against being switched on again Do not exchange any parts when under power Warning When components are being fitted or removed the su...

Страница 8: ...ing of the Control Panel Note For technical support contact Beckhoff Service 1 4 1 National regulations Depending on the type of machine and plant in which the Control Panel is used national regulations governing the controllers of such machines will apply and must be observed by the operator These regulations cover amongst other things the intervals between inspections of the controller The opera...

Страница 9: ... Extended technology enables remote panel operation at a distance of up to 50 m from the PC The Economy built in Control Panel offers the following benefits 10 1 inch TFT display 1024 x 600 WSVGA CP6900 0001 0000 or 7 inch TFT display 800 x 480 WVGA CP6906 0001 0000 aluminium front with sheet steel rear cover front side IP54 rear side IP20 touch screen without keys integrated DVI USB extension tec...

Страница 10: ...modated in a steel housing with aluminium front The Control Panel is installed in the front of control cabinets Risk of explosion Danger The Control Panel must not be used where there is a risk of explosion 2 3 Access to the connectors The connectors of the Control Panel are located at the lower rear side of the housing Picture Bottom view 8 CP6900 0001 0000 CP6906 0001 0000 ...

Страница 11: ... A twin circuit board mounting FCI 72309 0030B USB Double Receptacle A Type The two USB interfaces X102 X103 connector type A are used for connecting peripheral devices with USB connection USB2 0 standard is supported in a distance of up to 5 m from the PC from a distance of 5 m up to 50 m USB1 1 standard is supported Pin Signal Pin Signal 1 5V 3 D 2 D 4 GND 2 4 3 USB in X104 X104 USB type B PCB i...

Страница 12: ...4 The DVI E connection X 106 is used for transferring the video signal from the Industrial PC to the Control Panel The purely digital part DVI D is supported The graphics signal is transferred directly via a DVI cable over a distance of 50 m max Such a cable length leads to strong distortion of the graphics signal on arrival at the Control Panel The CP6906 Control Panel features a signal processor...

Страница 13: ...it 20 m for CP690x containing 20 m DVI cable 20 m CAT 5 cable for USB E USB to USB E converter CU8800 for mounting rail installation close to the PC and 1 m USB cable to connect the USB to USB E converter to the PC C9900 K425 Connecting kit 30 m for CP690x containing 30 m DVI cable 30 m CAT 5 cable for USB E USB to USB E converter CU8800 for mounting rail installation close to the PC and 1 m USB c...

Страница 14: ...ensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately 12 hours must be allowed before the unit is switched on 3 1 2 Unpacking Proceed as follows to unpack the unit 1 Remove packaging 2 Do not discard the original packaging Keep it for future relocation 3 Check the deliv...

Страница 15: ...el in such a way that reflections on the screen are avoided as far as possible Use the position of the screen as a guide for the correct installation height it should be optimally visible for the user at all times The Control Panel should not be exposed to direct sunlight When the unit is in its mounting position the ventilation openings must not be obstructed Avoid extreme environmental condition...

Страница 16: ...r the cutout dimension of the Control Panel see chapter Assembly dimensions the wall thickness is between 1 mm and 5 mm 1 Insert the Control Panel into the cutout 2 Release the clamping levers with a 2 5 mm Allen key 3 Turn the clamping levers to the side 4 Retighten the screws 14 CP6900 0001 0000 CP6906 0001 0000 ...

Страница 17: ... the cable 1 Strip insulation from the cable ends Length of stripped conductor is 8 9 mm 2 Screw together the cable ends in the 5 pole plug connector in accordance with wiring diagram Applying the strain relief Thread the lacing cord into that lower part of the stain relief housing Putting in the plug connector Put the plug connector into that lower part of the stain relief housing Tighten the lac...

Страница 18: ...ol Panel please adhere to the following order Disconnect the Control Panel from the power supply Connect all cables at the Control Panel and at the devices to be connected Ensure that all screw connections between connectors and sockets are tight Reconnect all devices to the power supply 4 2 2 Earthing measures Earthing connections dissipate interference from external power supply cables signal ca...

Страница 19: ...switched off as the software is writing a file to the storage medium the file will be destroyed Control software typically writes something to the storage medium every few seconds so that the probability of causing damage by switching off while the software is running is very high Switch off power supply Warning When you have shut down the Industrial PC you have to switch off power supply for at l...

Страница 20: ...ency procedures In case of fire the Control Panel should be extinguished with powder or nitrogen 5 5 Shutting down 5 5 1 Disposal Observe national electronics scrap regulations Note Observe the national electronics scrap regulations when disposing of the device In order to dispose of the device it must be removed and fully dismantled Housing components polycarbonate polyamide PA6 6 are suitable fo...

Страница 21: ...arts but control does not operate correctly Cause of the fault is either in the software or in parts of the plant outside the Industrial PC Call the manufacturer of the machine or the software USB error while TwinCAT access via USB Cycle time in TwinCAT is set on 10 ms standard Increase the cycle time up to 50 ms till 80 ms The Control Panel functions only partially or only part of the time e g no...

Страница 22: ...P6900 0001 0000 Notice mounting orientation Warning The assembly of the unit must take place with the orientation diagrammed here All dimensions are in mm Front view Rear view with cutout dimensions Side view 20 CP6900 0001 0000 CP6906 0001 0000 ...

Страница 23: ...ce mounting orientation Warning The assembly of the unit must take place with the orientation diagrammed here All dimensions are in mm Ansicht von vorne Front view Rear view with cutout dimensions Side view CP6900 0001 0000 CP6906 0001 0000 21 ...

Страница 24: ...DVI E input is compatible to the standard DVI output of a PC Interfaces 2 Port USB 2 0 USB 1 1 Protection class Front side IP54 rear side IP20 Shock resistance Sinusoidal vibration EN 60068 2 6 10 to 58 Hz 0 035 mm 58 to 500 Hz 0 5 G 5 m s2 Shock resistance Shock EN 60068 2 27 5 G 50 m s2 duration 30 ms EMC compatibility Resistance to interference conforms to EN 61000 6 2 EMC compatibility Emissio...

Страница 25: ...orstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 E mail info beckhoff de Web http www beckhoff de Beckhoff Support Support offers you comprehensive technical assistance helping you not only with the application of individual Beckhoff products but also with other wide ranging services world wide support design programming and commissioning of complex automation systems and ...

Страница 26: ...is equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical modifications Note ...

Отзывы: