Foreword 

 

 

1.2  Description of safety symbols 

The following safety symbols are used in this operating manual. They are intended to alert the reader to 
the associated safety instructions. 

Acute risk of injury! 

 

DANGER 

If you 

do not

 adhere the safety advise adjoining this symbol, there is immediate 

danger to life and health of individuals! 

 

Risk of injury! 

 

WARNING 

If you 

do not

 adhere the safety advise adjoining this symbol, there is danger to life and 

health of individuals! 

 

Hazard to individuals! 

 

CAUTION 

If you 

do not

 adhere the safety advise adjoining this symbol, there is obvious hazard to 

individuals! 

 

Hazard to devices and environment 

 

Attention 

If you 

do not

 adhere the notice adjoining this symbol, there is obvious hazard to 

materials and environment. 

 

Note or pointer 

 

Note 

This symbol indicates information that contributes to better understanding. 

 

4

 

CP29xx 

Содержание CP29xx-0000 Series

Страница 1: ...stallation and Operating instructions for CP29xx 0000 Multi touch Control Panel with DVI USB Extended interface CP29xx 0010 Multi touch Control Panel with CP Link 4 interface Version 1 9 Date 2018 11...

Страница 2: ......

Страница 3: ...Access to the connectors 8 2 4 Interfaces CP29xx 0000 10 2 4 1 DVI E Input Digital Visual Interface Extended X106 10 2 4 2 USB Extended Input X 105 10 2 4 3 USB in X 104 11 2 4 4 USB out X 102 X 103 1...

Страница 4: ...22 5 Operating Instructions 23 5 1 Switching the Control Panel on and off 23 5 1 1 Switching on 23 5 1 2 Shutting down and switching off 23 5 2 Operation 23 5 3 Servicing and maintenance 24 5 3 1 Cle...

Страница 5: ...C and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH Other designations used in this publication may be trademarks whose use by third parties for their own purposes could vi...

Страница 6: ...duals Risk of injury WARNING If you do not adhere the safety advise adjoining this symbol there is danger to life and health of individuals Hazard to individuals CAUTION If you do not adhere the safet...

Страница 7: ...ir all parts of the equipment must first be switched off after which the Control Panel is to be disconnected from the equipment Disconnect the device by unplugging the connectors on the rear side of t...

Страница 8: ...pen the housing of the Control Panel Note For technical support contact Beckhoff Service 1 4 1 National regulations Depending on the type of machine and plant in which the Control Panel is used nation...

Страница 9: ...3 landscape and portrait orientation multi touch PCT e g for 5 finger or 2 hand touch operation high touch point density for safe operation aluminium housing with glass front front side IP65 rear side...

Страница 10: ...nce of up to 50 m from the PC via a standard cable The CP Link 4 connection technology integrated in the CP29xx 0010 Control Panel enables remote panel operation at a distance of up to 100 m from the...

Страница 11: ...Product Description Connection block CP29xx 0010 For the pin assignment see chapter Interfaces CP29xx 0010 CP29xx 9...

Страница 12: ...he CP29xx Control Panel features a signal processor that restores the DVI signal The PC requires a conventional DVI output Pin Signal Pin Signal 1 Rx2 13 Rx3 2 Rx2 14 5V DVI 3 GND 15 GND 4 Rx4 16 HPD...

Страница 13: ...supported in a distance of up to 3 m from the PC from a distance of 3 m up to 50 m or if using USB Extended USB2 0 standard is supported Pin Signal Pin Signal 1 5V 3 D 2 D 4 GND 2 4 5 Ground connecti...

Страница 14: ...up to 100 m away from the PC CP Link 4 transfers DVI and USB together via a CAT 6A cable The CU8802 CP Link 4 transmitter box is connected to the PC via DVI and USB or else the C9900 E276 PCIe module...

Страница 15: ...ins unchanged The CU8803 sender box provides power to the Control Panel via the CAT 6A cable which also transfers DVI and USB The power supply socket of the panel is not used Don t connect power suppl...

Страница 16: ...nk 4 Input X104 X104 BA 1x8pole RJ45 Invers shield 2XLWL Lp mount Molex Nr 43860 0016 Modular Jack The Control Panel is connected with the PCIe module slot of the Industrial PC or the transmitter box...

Страница 17: ...e Control Panel is established via the socket X101 see chapter CP Link 4 Architecture Description The power supply connector is included in delivery Pin Signal Pin Signal 1 NC 4 GND 2 NC 5 24 VDC Powe...

Страница 18: ...C9900 K627 Connecting kit 30 m for CP29xx containing 30 m DVI cable 30 m CAT 5 cable for USB E 2 0 USB to USB E 2 0 converter CU8801 for mounting rail installation close to the PC and 1 m USB cable t...

Страница 19: ...nnecting cable RJ45 CAT 6A 90 m C9900 K682 Connecting cable RJ45 CAT 6A 100 m C9900 K725 Connecting cable RJ45 CAT 6A 3 m suitable as trailing cable C9900 K713 Connecting cable RJ45 CAT 6A 5 m suitabl...

Страница 20: ...oisture condensation does not form on or inside the device Prior to operation the unit must be allowed to slowly adjust to room temperature Should condensation occur a delay time of approximately 12 h...

Страница 21: ...to direct sunlight When the unit is in its mounting position the ventilation openings must not be obstructed Avoid extreme environmental conditions Attention Extreme environmental conditions should b...

Страница 22: ...levers For the cutout dimension of the Control Panel see chapter Assembly dimensions the wall thickness is between 1 mm and 5 mm 1 Insert the Control Panel into the cutout 2 Release the clamping leve...

Страница 23: ...is fitted to the cable 1 Strip insulation from the cable ends Length of stripped conductor is 8 9 mm 2 Screw together the cable ends in the 5 pole plug connector in accordance with wiring diagram Appl...

Страница 24: ...onnections are located at the rear of the Control Panel and are documented in the chapter Interfaces When connecting cables to the Control Panel please adhere to the following order Disconnect the Con...

Страница 25: ...ing off while the software is running is very high Switch off power supply Warning When you have shut down the Industrial PC you have to switch off power supply for at least 10 seconds before rebootin...

Страница 26: ...ree 5 4 Emergency procedures In case of fire the Control Panel should be extinguished with powder or nitrogen 5 5 Shutting down 5 5 1 Disposal Observe national electronics scrap regulations Note Obser...

Страница 27: ...operate correctly Cause of the fault is either in the software or in parts of the plant outside the Industrial PC Call the manufacturer of the machine or the software Malfunction of the touchscreen B...

Страница 28: ...lease visit our homepage Here you will find the actual drawings using the link http download beckhoff com download Technical_Drawings Industrial_PC Control_Panel CP29xx Notice mounting orientation War...

Страница 29: ...with 480 Mbit s DVI E input is compatible to the standard DVI output of a PC CP29xx 0010 Integrated CP Link 4 technology enables remote panel operation at a distance of up to 100 m from the PC via a C...

Страница 30: ...Co KG Huelshorstweg 20 33415 Verl Germany Phone 49 0 5246 963 0 Fax 49 0 5246 963 198 E mail info beckhoff de Web http www beckhoff de Beckhoff Support Support offers you comprehensive technical assis...

Страница 31: ...nerates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equ...

Отзывы: