Product Description
CP-Link 4 cables with above 60 m cable-length with ferrite core
Note
CP-Link 4 cables with above 60 m cable-length are fitted with a ferrite core at one end.
If connecting the cable make sure to plug in the cable as shown in the picture with the
ferrite core Control Panel-sided.
ferrite core
CP-Link 4 cable connection
2.5.5 Power Supply (X101)
X101
Socket 5-pol RM3.50 Sw Screw Clamp BL3.5/180F (WEIDMÜLLER 1615810000)
The optional power supply for the Control Panel is established via the socket
(X101)
, see chapter
CP-Link 4 Architecture Description.
The power supply connector is included in delivery.
Pin
Signal
Pin
Signal
1 NC
4 GND
2 NC
5 + 24 V
DC
Power Supply
3
Don’t connect power supply socket if using One Cable technology
Attention
If using the CP-Link 4 - One Cable Display Link technology, do not connect anything to
the power supply socket of the Panel.
2.5.6 Ground connection
The Control Panel is grounded via the screw connection (
Ground
).
Malfunction possible with missing ground connection
Note
A proper ground connection of the device is absolutely necessary for the correct
function of the touchscreen.
CP29xx
15