Product overview
C6017
14
Version: 2.1
3.3
Optional interfaces
You can extend the Industrial PC beyond the basic configuration by additional interfaces. The following
ordering options are available:
• Ethernet RJ45 and USB 2.0 (order identifier: C9900-E302)
• RS232 (order identifier: C9900-E311)
Further interfaces are available on request. Any interfaces that are ordered are installed ex factory.
3.3.1
USB 2.0
The Industrial PC optionally contains two additional USB interfaces. Both support the USB 2.0 specification.
They each supply up to 500 mA current and are electronically protected.
They are used to connect peripheral devices with USB interfaces.
1 2 3 4
4
3
2
1
Fig. 6: C6017_USB interface pin numbering
Table 8: USB interface pin assignment
Pin
Connection
Typical assignment
1
VBUS
Red
2
D -
White
3
D +
Green
4
GND
Black
Shell
Shield
Drain Wire
3.3.2
Ethernet RJ45
The two additional Ethernet ports enable connection of corresponding network components with data rates
of 100/1000 Mbit/s in accordance with the 100Base-T and 1000Base-T Ethernet standards.
The RJ45 connection technology with twisted-pair cables is used. The maximum length of the cable
connection is 100 m.
The Intel
®
i210 (MAC/PHY) controller is used for both ports.
The Ethernet ports are not switched. They are suitable for cycle times <= 1 ms and for distributed clock
applications in EtherCAT.
8
1
1
8
Fig. 7: C6017_Ethernet interface pin numbering