Fault correction
58
───
Version: 1.0
AA3000
Number
Cause
Solution
1
Servo drive not enabled
Set ENABLE signal and enable servo drive
Motor overload
Check the load and if necessary reduce it, then
restart and enable the servo drive. Set EN-
ABLE signal
Mechanical blockage of the motor
Check mechanics and release blockage
Holding brake [+] not released
Check the control configuration of the holding
brakes [+] and reconfigure if necessary
2
Phase interruption in the power supply or reversed
motor phases
Check servo drive and supply cables and re-
place any defective cables
3
Phase interruption after power supply; switching on Check servo drive and supply cables and re-
place any defective cables
Power cable or feedback line with defective shield
Check ground connection and shielding
4
Short-circuit in the voltage supply cable for the
holding brake [+]
Replace defective cable, measure and check
cable after replacement
Output voltage of the servo drive too low
Check the settings in the configuration and
read out the electronic identification plate of
the motor again
Defective holding brake [+]
Replace motor, then measure and check
5
Short circuit or earth leakage in the motor line
Replace defective motor line, then measure
and check
6
Power connector not fitted correctly
Check the connectors on the power connector
and on the motor
Interruption in the feedback or motor line
Check cables for wire break or crushing. Re-
place defective cables, then measure and
check.
Содержание AA3000
Страница 1: ...Operating instructions EN AA3000 Electric cylinders 1 17 2022 Version 1 0 ...
Страница 2: ......
Страница 28: ...Technical data 28 Version 1 0 AA3000 4 3 1Dimensional drawing All figures in millimeters ...
Страница 30: ...Technical data 30 Version 1 0 AA3000 4 4 1Dimensional drawing All figures in millimeters ...
Страница 32: ...Technical data 32 Version 1 0 AA3000 4 5 1Dimensional drawing All figures in millimeters ...
Страница 66: ......