Adjustable parameters
parameter
text in display
settings in display line 2
no.
line
1
range
function
19-29
required series f [Hz]
0-200
default speed of rotation for standard set
19-30
sensortype
0-3
Default
sensor
1 Vakuum sensor 0-1
2
Pressure
1,0-2,6
3
Danfoss
0-4
19-31
operation p/v
-1
vacuum operation
1
pressure
operation
19-32
P factor
0-10000
proportional-factor
19-33
I factor
0-10000
integral-action factor
19-34
D factor
0-10000
differentiality factor
19-37
internal nominal value [mbar] 200-1000
vacuum operation
1000-2000
pressure operation
19-38
process with/without
-1
without PI control
1
with
PI
control
19-39
Series/Test
-1
test
operation
1
series operation
19-40
Valve open [mbar]
0-2000
opening the solenoid valve
19-41
Valve close [mbar]
0-2000
closing the solenoid valve
19-42
Switch-off time [min]
1-10
maximum time for the exceeding of the
pressure
limit
19-43
SPS y/n
-1
without external control
1
with
external
control
19-44
SPS required value
-1
without external nominal value source
1
with
external
nominal
value
source
19-45
SPS required value
-1
not invert nominal value signal
1 invert
nominal
value
signal
Содержание VARIAIR DIRECT SCREW 1500
Страница 1: ...28100031100 08 2017 Page 1 Operating Manual DIN EN ISO 9001 001929 QM DIN EN ISO 9001 001929 QM...
Страница 17: ...28100031100 08 2017 Page 17 Pressure side LA Suction side SA Operating panel Main switch Figure 1...
Страница 19: ...28100031100 08 2017 Page 19 oil cooler fan suction filter Figure 3 oil filler neck VADS 1500 45 KW...
Страница 20: ...28100031100 08 2017 Page 20 pressure pipe magnetic bypass valve Figure 4 exhaust silencer VADS 1500 45 KW...
Страница 23: ...28100031100 08 2017 Page 23 oil cooler fan suction filter Figure 6 oil filler neck VADS 1500 37 KW...
Страница 24: ...28100031100 08 2017 Page 24 exhaust pipe magnetic bypass valve VADS 1500 37 KW Figure 7...