Other malfunctions
Problem
Cause
Remedial action
Unit does not start-up when
Parameter 19-43 “SPS Y/N”
Change parameter 19-43 to
value -1
pressing
[START]
key
was set to the
value 1
Unit does not start-up when
Previous manual stop
Press
[START]
key
running in automatic/SPS mode
SPS release signal missing at clamp 18
Check the electric wiring of the release line
or SPS signal
System pressure in display line 2
Defect of wiring or pressure sensor
Check wire connection to pressure
is not displayed sensor
Display is not set to parameter 95
Change display to parameter 95