27
What should you do, if...?
Malfunction
Cause
Solution
Tubular.drive.is.not.running.
1.. No.transmitter.has.been.programmed.
2.. Transmitter.is.outwith.the.range.of.the.
tubular.drive.
3.. Transmitter.has.been.operated.outwith.the.
range.several.times.
4.. Batteries.in.the.transmitter.have.been.in-
correctly.inserted,.not.inserted.at.all.or.are.
empty.
5.. Faulty.electrical.connection.
6.. Thermal.cut-out.function.in.the.tubular.
drive.has.been.activated.
1.. Programme.new.transmitter.
2.. Move.transmitter.into.the.range.of.the.
tubular.drive.
3.. Activate.the.control.or.stop.button.on.the.
transmitter.at.least.5.times.
4.. Insert.batteries.properly.or.replace.batte-
ries.
5.. Check.electrical.connection.
6.. Wait.5-10.minutes.
You.are.unable.to.change.the.
axle.direction.
End.limits.are.stored.in.the.tubular.drive.
Start.up.the.tubular.drive.via.a.start.command.
and.deactivate.with.a.stop.command..Then.
delete.the.end.limit.settings.using.the.pro-
gramming.and.stop.buttons.
Tubular.drive.has.stopped.at.
random.and.won’t.run.in.the.
given.direction.
1.. Tubular.drive.has.detected.an.assumed.
load.
2.. Tubular.drive.is.overloaded.
1.. Run.the.drive.briefly.in.the.opposite.direc-
tion,.then.activate.the.desired.direction.
again.
2.. Use.a.tubular.drive.with.a.greater.torque.
Tubular.drive.is.not.adjusting.
the.shutters.into.the.preset.
ventilation.and.intermediate.
positions.
The.upper.end.limit.has.been.set.first.
The.end.limits.have.to.be.reset..Remember.to.
set.the.lower.limit.first!