Explanation of functions
Manual/Automatic slide switch
In slide switch position " " only manual drive commands and alarm signals can
be performed (e.g.: UP, STOP, DOWN via button actuation).
Automatic drive commands are performed with the slide switch in the "
"
position (control signals via group control inputs).
When using transmitters TC4410-II and SWC745-II, only the
"MANUAL/AUTOMATIC" setting on the transmitter is author-
itative.
Alarm signal
An alarm signal (e.g. wind) is signalled by an illuminated indicator lamp. A con-
tinuous switching signal at the group or individual control inputs for longer
than 5 seconds is deemed an alarm signal.
The ALARM SIGNAL function can be switched on/off via the coding switch 1.
Group control unit
Several drives controlled simultaneously are referred to as a group.
RESET button
Intermediate position I, intermediate position II and the memory run times can
be deleted by pressing the RESET button (with a ballpoint pen or similar ob-
ject).
Intermediate position I
The intermediate position I is any shading solution position of your choosing,
situated between the upper and lower limit positions. Once programmed, this
position can be travelled to from the upper position.
To do so, press the
DOWN
button briefly
twice
in succession.
For venetian blind operation, any tilt (intermediate position II) which has been
set is automatically carried out following the intermediate position I.