background image

Disassembling the plug-in connecting cable for tubular drives dia. 45 and dia. 58

Caution

Prior to disassembly, the power supply to the connecting cable must be disconnected.

Insert a suitable flathead screwdriver right into the recess of the locating latch, so that the latch releases the locating lug from the
plug.

Now you can pull out the connecting cable along with the flathead screwdriver.

dia. 45 and dia. 58

1.

2.

A

A = locating latch

7

Содержание C01a

Страница 1: ...integrated radio receiver 915 3 Mhz Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Straße 2 4 35764 Sinn Germany www becker antriebe com 2010 300 570 0d 14 08 2018 ...

Страница 2: ...ng and disassembling the drive adapter with screw connection 9 Mounting the drive in the tube 10 Confirming the drive 11 First operation 12 Programming the master transmitter 13 Checking that the running direction is correct 13 Intelligent installation management 14 Setting the limit positions 14 Upper stop to lower stop 14 Upper point to lower point 15 Upper stop to lower point 15 Upper point to ...

Страница 3: ...nder it Suitable for rigid aluminium steel and wooden profiles The final positions do not have to be reset Changes in the shading solution are accommodated automatically when using stop systems Torque control in the up direction prevents damage to the roller shutter in the event of a frozen or blocked shutter Anti freeze mechanism in the upper limit position can be enabled Considerably lower stop ...

Страница 4: ...volved Children must not play with the device Systems have to be checked regularly by authorised specialists for wear and damage Always put damaged systems out of operation immediately until they are repaired by an authorised specialist Do not operate equipment if people or objects are within the danger zone Observe the danger zone of the equipment during operation Ensure that there is adequate cl...

Страница 5: ... shading solutions in a specially marked area e g escape routes hazard zones safety areas compliance with all applicable regulations and standards must be ensured Caution Safety instructions for avoiding serious injuries When electrical or electronic equipment and units are operated certain components e g the power supply unit are live Physical injuries or damage to property can result in the even...

Страница 6: ...s and others since these ac tions can impair the system s safety and carry the risk of personal injury and property damage The drive manufacturer does not accept liability for damages or injury arising from such actions Always observe the information in these instructions when operating or repairing the system The drive manufacturer does not ac cept liability for damage or injury resulting from im...

Страница 7: ...wer supply to the connecting cable must be disconnected Insert a suitable flathead screwdriver right into the recess of the locating latch so that the latch releases the locating lug from the plug Now you can pull out the connecting cable along with the flathead screwdriver dia 45 and dia 58 1 2 A A locating latch 7 ...

Страница 8: ...ps in the guide tracks Calculate the space required at the side M by measuring the drive head 1 and wall bracket 2 The clear dimension of the box X minus the space required at the side M and idler G gives the length L of the barrel L X M G The space required at the side M varies depending on the combination of drive and wall bracket Then mount the wall bracket and idler Ensure that the barrel is a...

Страница 9: ...the drive adapter with safety catch on the drive shaft Disassembly with disassembly tool Item no 4930 300 606 0 Disassembly with long nose pliers 2 1 Assembling and disassembling the drive adapter with separate drive adapter safety catch Assembling and disassembling the drive adapter with screw connection 9 ...

Страница 10: ...f tapping screw dia 6 3 x 13 mm We also recommend screwing the idler to the barrel Attention Do not hammer the tubular drive into the tube or drop it into the barrel The curtain can only be secured using springs or rigid shaft connectors We recommend at least three pieces per metre of barrel Assemble the tubular drive with the relevant ring 1 and drive adapter 2 If the ring has several grooves sel...

Страница 11: ...Confirming the drive The drive confirms each programming and deletion action The tubular drive does this through a small movement that can be per ceived audibly as clicking or visually as shifting 11 ...

Страница 12: ...system is ready for operation again The drive does not achieve its full duty cycle until it has cooled to ambient temperature Avoid a situation where the thermal protection switch cuts in repeatedly N 1 2 1 2 4 3 4 230V AC 50 Hz L1 PE Connecting the tubular drive Connect the tubular drive to the power supply 1 blue 3 black 2 brown 4 green yellow Readying the tubular drive for programming Readying ...

Страница 13: ...d on the receiver press the programming button for 10 seconds Checking that the running direction is correct There are 2 ways to change the direction of rotation Changing direction of rotation via rotation direction switch Changing direction of rotation via master transmitter Changing direction of rotation via rotation direction switch Press the UP or DOWN button The shading solution runs in the d...

Страница 14: ...tter The shutter direction must be correct When setting the limit positions the tubular drive runs in dead man mode with the limit position status indicator The upper limit position must always be set first When setting the upper limit position ensure that the roller shutter curtain is not pulled out of the guide tracks When first installing using springs and adjusting the limit position to lower ...

Страница 15: ...e limit positions are now set Upper stop to lower point Open to the permanent upper stop The tubular drive switches off automatically Then close to the desired lower limit position Press the programming button and within 3 seconds also press the DOWN button and hold the two buttons down The tubular drive acknowledges The limit positions are now set Upper point to lower stop Open to the desired upp...

Страница 16: ...nction are deleted as well Open close to the limit position in the direction in which you wish to extend the range of travel Press the programming button and within 3 seconds also press the STOP button and hold the two buttons down for 10 seconds The tubular drive acknowledges The limit position is now deleted Open close to the desired new limit position Press the programming button and within 3 s...

Страница 17: ... positions I II The intermediate positions I II are freely selectable positions for the shading solution between the two limit positions Each travel button can be assigned one intermediate posi tion Both limit positions must be set before an intermediate position is set Setting the desired intermediate position Open close the shading solution to the desired intermediate position Press the STOP but...

Страница 18: ...r drive for 3 seconds Doing so activates the programming mode of the tubular drive for a new transmitter for 3 minutes The tubular drive acknowledges Now press the programming button of the new transmitter you wish to program again for 3 seconds The tubular drive acknowledges The new transmitter has now been programmed Deleting transmitters Deleting individual transmitters The programmed master tr...

Страница 19: ...n the power To ensure that the new master transmitter is programmed in the desired tubular drive only all other tubular drives which are connected to the same power supply must be deactivated from the programming mode To do so after switching back on the power execute a drive or stop command using the transmitter for the given tubular drives or switch the radio switch from inside to outside If the...

Страница 20: ...ready in this posi tion switch it to the outside and back to the inside position The tubular drive is ready to program for 3 minutes Now press the programming button of the new master transmitter for 10 seconds The tubular drive acknowledges The new master transmitter has now been programmed and the old master transmitter overwritten 20 ...

Страница 21: ...onds after the mains voltage has been switched on N L PE Button normally open black brown blue green yellow Button commands 1 second Moves in maintained operation 1 second Moves in dead man mode Double tap 1 second Moves to the intermediate position in alternation if both are programmed Operation proceeds in this sequence Travel Stop Travel in the opposite direction Stop 21 ...

Страница 22: ...nd of the thrust ring Use of the drive s obstacle detection system as personal protection is not permitted It has been designed exclusively to protect the roller shutters or sun protection system from be ing damaged If the drive is correctly installed it switches off when it detects obstructions or shutter faults and reverses a short way in the oppos ite direction and thus away from the obstacle I...

Страница 23: ...on function Open the shading solution to the upper limit position Then re press the programming button and also the STOP and UP buttons for ap prox 3 seconds The tubular drive acknowledges Disposal This product is made of various materials which must be disposed of properly Find out about the applicable regulations on recyc ling or disposal for this product in your country The packaging material m...

Страница 24: ...direction then continue in the desired direction Tubular drive is overloaded Use a higher torque tubular drive Switching times cannot be set on tubular drive Use transmitter with manual auto slide switch Tubular drive does not operate at the set switching time Switch manual auto slide switch to Switch the slide switch on one transmitter from to If the slide switch is already at switch it to and ba...

Страница 25: ...Sample wiring diagram N L PE Electronics Black Brown Blue Green yellow 25 ...

Страница 26: ...26 ...

Страница 27: ...27 ...

Страница 28: ......

Отзывы: