Deleting individual limit positions
Open/close to the limit position to be deleted.
Press the programming button and, within 3 seconds, also press the STOP button
and hold the two buttons down for 10 seconds.
▻
The tubular drive acknowledges.
►
The limit position is now deleted.
Deleting both limit positions
Open/close the shading solution to a point between the limit positions.
Press the programming button and, within 3 seconds, also press the STOP button
and hold the two buttons down for 10 seconds.
▻
The tubular drive acknowledges.
►
The limit positions are now deleted.
Intermediate positions I + II
The intermediate positions I + II are freely selectable positions for the shading solution
between the two limit positions. Each travel button can be assigned one intermediate posi-
tion. Both limit positions must be set before an intermediate position is set.
Setting the desired intermediate position
Open/close the shading solution to the desired intermediate position.
Press the STOP button and, within 3 seconds, also press the desired travel button
and hold the two buttons down.
▻
The tubular drive acknowledges.
►
The intermediate position is now saved.
Travelling to the desired intermediate position
Press the travel button for the desired intermediate position twice within one second.
►
The curtain runs to the intermediate position assigned to the travel button.
17
Содержание C01a
Страница 25: ...Sample wiring diagram N L PE Electronics Black Brown Blue Green yellow 25 ...
Страница 26: ...26 ...
Страница 27: ...27 ...
Страница 28: ......