Operating Instructions
42
Caution
• Risk of injury through an electric shock.
• Terminal connections must be carried out by an authorised electrician!
• If more than one drive is controlled using the TC52, the drives must be
decoupled by relay controls. This decoupling is not applicable to Becker drives
with electronic limit stop.
Take into consideration the switched current of the device.
Light sensor
Explanations
Note
A light sensor can be connected to the device. See operating instructions for the
Centronic SensorControl SC43 .
MAN/AUTO sliding switch
In the
„MAN“
sliding switch setting, only manual command controls are carried out (e.g.:
UP, STOP, DOWN by pressing the relevant buttons).
In the
„AUTO“
sliding switch setting, automatic command controls are carried out (e.g.
shade function, twilight function, time, astro function,...)
Alarm signal control light
When the alarm signal control light is illuminated, this indicates an alarm signal. If there
is a permanent switching signal at the group or individual control inputs for more than 5
seconds, it is an alarm signal.
Group control
Group control is control of several drives at the same time.
Operating mode
You will see the time and the current operating mode e.g. HOLIDAY in the display.
OK button
When the
OK
button is pressed, the currently displayed values are saved.