Device Configuration
Advanced Setup
– Serial (RS232 Console Port)
74
BEC MX-200Ae User Manual
TCP Server:
◼
Port:
Use 782(tcp/udp), an unassigned port, for the TCP Server. Specify a tcp/udp port
other than port 782.
◼
Empty Serial Buffer When TCP Connection is Established:
When TCP link connection
is established, serial buffer will get deleted. Enable to empty the buffer after TCP
connection is up.
◼
Data packet Delimiter:
A way to keep packets in tract.
⚫
Inter-character Time Gap:
Default time is in 1000ms. After time has reached, serial
data will be transmitted. Time range from 1
– 30000ms.
⚫
Character Delimiter:
Default characters are 0x0d0a. Serial data will get transmitted
when seeing the specified character(s), in this case, 0x0d0a. Valid characters “0x” +
Hex code
◼
TCP Idle Timeout (Seconds):
Default time is in 60 seconds. Specify an idle time-out in
seconds. After the timeout expires, meaning no data transmission within the defined time,
serial connection will get aborted. Time range from 10
– 180 seconds
TCP Client:
◼
Remote Host Name / IP:
Enter either TCP server’s name or IP address.
◼
Port:
Generally uses port 782(tcp/udp). Specify tcp/udp port other than port 782.
◼
Empty Serial Buffer When TCP Connection is Established:
When TCP link connection
is established, serial buffer will get deleted. Enable to empty the buffer after TCP
connection is up.
◼
Data packet Delimiter:
A way to keep packets in tract.
⚫
Inter-character Time Gap:
Default time is in 1000ms. After time has reached, serial