User’s Guide for product version 

0100

 and higher

See product label for serial number

COMPACT LASER SCANNER FOR SLIDING DOOR

Содержание LZR-FLATSCAN SL

Страница 1: ... FLATSCAN SLrecessed PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING EN User s Guide for product version 0100 and higher See product label for serial number COMPACT LASER SCANNER FOR SLIDING DOOR ...

Страница 2: ...screw 3 Laser screen 4 Connector 5 Push button 6 Laser window protection 7 Front cover 8 DIP switch 9 Power cable DESCRIPTION Caution Laser radiation Remote control sequence Possible remote control adjustments Factory values Attention Note The LZR FLATSCAN SLrecessed is a multi functional sensor for automatic sliding doors based on laser technology It secures the door closing area and also offers ...

Страница 3: ...ut a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The sensor manufacturer cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel INSTALLATION AND MAI...

Страница 4: ...remote control access Only the safety field responded relay would respond for the test INSTALLATION OF THE SENSOR Install the sensor at the right position and fix it with the screws When DIP2 is OFF critical environments testbody CA EN 16005 might not be detected Switch to CRITICAL when external disturbances are likely to cause unwanted detections Switch to OFF when there is no background e g glas...

Страница 5: ...LE SPOTS ADJUSTMENTS SETTINGS Quickly press the push button twice to activate the visible spots they will help you position the curtain Quickly double click to activate or deactivate the visible laser spots Press for 2 seconds to launch a safety field teach in process Press for 3 seconds to confirm the setting after changing the DIP switch Press for 5 seconds to acknowledge the 6x flashing error me...

Страница 6: ...the left right limit of the detection field The LED flashes red while calculating 3 Wait until the sensor flashes green again Stretch out your arm in front of you and make an up and down movement to define the right left limit of the detection field The LED flashes red while calculating 4 Once the LED is off the teach in is complete With the remote control Left detection area Safety field teach in...

Страница 7: ...o change these settings by remote control adjust DIP switch 4 to ON The LED turns green if there is a detection in VPB areas The LED turns red if there is a detection in safety areas The LED also turns green if there is a detection in both areas OUTPUT REDIRECTION Left or right FRONT FACE Clasp the front cover to finish the installation Protect the laser window in case of construction works VPB1 W...

Страница 8: ...can be adjusted with the remote control If the red LED flashes quickly after unlocking you need to enter an access code from 1 to 4 digits If you do not know the access code cut and restore the power supply During 1 minute you can access the sensor without introducing any access code To end an adjustment session always lock the sensor ADJUSTING ONE OR MORE PARAMETERS When there are several sensors...

Страница 9: ...field of 1cm TEACH IN turn on off the visible spots factory reset of all values factory reset of all values except field dimensions output redirection and configuration disable the output and LED for 15 minutes and can be helpful during an installation a mechanical teach in of the door or maintenance work VISIBLE SPOTS SERVICE MODE RESET TO FACTORY SETTINGS refer to the teach in process on page 5 ...

Страница 10: ... Launch a new safety field teach in Unwanted detections due to environment or external conditions 1 Make sure the laser curtain at the correct position 2 Verify if the laser window is dirty and clean it carefully with a damp and clean microfibre cloth if necessary attention the surface of the laser window is delicate 3 Switch DIP 2 to off critical environment The sensor does not react at power on I...

Страница 11: ...lose to the sensor is masking part of the detection field 1 Make sure the laser window is not scratched If it is replace sensor 2 Remove all masking elements insects spider web flexible tube laser window protection 3 Verify if the laser window is dirty and clean it with compressed air Then wipe it carefully with a damp and clean microfibre cloth if necessary attention the surface of the laser wind...

Страница 12: ...polarity free Max switching voltage 42V AC 60V DC Max switching current 100 mA 1 Relay free of potential change over contact Max contact voltage 60V AC 125V DC Max contact current 1 0A resistive Max switching power 30W DC 60VA AC LED signals 1 bi coloured LED detection output status Dimensions 178 mm L 85 mm H 53 mm D Material Colour PC ABS Black Tilt angles 0 to 5 Protection degree IP54 IEC EN 60...