System air conditioner

OPERATION MANUAL

REYQ8PY1B
REYQ10PY1B
REYQ12PY1B
REYQ14PY1B
REYQ16PY1B

English

Deutsch

Français

Español

Italiano

Ελληνικ

Ü

Nederlands

Portugues

Р

ó

сс

ê

ий

Türkçe

Operation manual

VRV

III

 System air conditioner

Betriebsanweisung

VRV

III

 System Klimaanlage

Manuel d’utilisation

Conditionneur d’air VRV

III

 System

Manual de operación

Sistema de acondicionador de aire VRV

III

Manuale d’uso

Condizionatore d’aria a sistema VRV

III

Εγχειρ

ß

διο

 

λειτουργ

ß

α

ò

Κλι

ì

ατιστικ

ü ì

ε

 

σ

ý

στη

ì

α

 VRV

III

Gebruiksaanwijzing

Airconditioner met VRV

III

 Systeem

Manual de funcionamento

Ar condicionado VRV

III

 System

Р

óê

оводство

 

по

 

э

ê

спл

ó

атации

Кондиционер

 

системы

 VRV

III

Kullaným kýlavuzu

VRV

III

 System Klima

00_CV_3P201178-2B.fm  Page 1  Wednesday, April 25, 2007  3:47 PM

Summary of Contents for VRV III REYQ10PY1B

Page 1: ...VRVIII System Klimaanlage Manuel d utilisation Conditionneur d air VRVIII System Manual de operación Sistema de acondicionador de aire VRVIII Manuale d uso Condizionatore d aria a sistema VRVIII Εγχειρßδιο λειτουργßαò Κλιìατιστικü ìε σýστηìα VRVIII Gebruiksaanwijzing Airconditioner met VRVIII Systeem Manual de funcionamento Ar condicionado VRVIII System Рóêоводство по эêсплóатации Кондиционер сист...

Page 2: ...ità interna in un luogo sicuro Dopo aver ricevuto il documento di garanzia dal rivendi tore conservarlo in un luogo sicuro Σαòευχαριστοýìε που αγορÜσατεαυτüτο κλιìατιστικü Daikin ÄιαβÜστε προσεκτικÜαυτüτο εγχειρßδιοχειρισìοý πρινχρησιìοποιÞσετετο κλιìατιστικü ΘασαòενηìερþσεισχετικÜìετοντρüποχρÞσηòτηòìονÜδαò καιθασαò βοηθÞσει ανπροκýψουνπροβλÞìατα ΑφοýδιαβÜσετε το εγχειρßδιο φυλÜξτετοσεασφαλÝòìÝροò...

Page 3: ...2 1 4 3 5 6 7 1 7 3 7 2 ...

Page 4: ...8 9 10 11 12 Ceiling Suspended Wall Mounted Double flow Multi flow Corner 13 1 15 14 13 2 Ceiling Suspended Wall Mounted Double flow Multi flow Corner ...

Page 5: ...in contact with any kind of heater stove or other sim ilar objects Turn off any combustible heating devices ventilate the room and contact the dealer where you pur chased the unit When repairing a refrigerant leak have a service engineer check that the repair has been per formed properly before running the unit again Use only fuses of the correct capacity if a fuse load switch is being used Using ...

Page 6: ...e sure to stop the operation and turn the breaker off before cleaning This may cause electric shock and injury Consult with the dealer for cleaning the interior of the indoor units Incorrect cleaning may damage the plastic parts and cause failures such as water leakage and an electric shock may result Do not locate objects around the outdoor unit and do not let leaves and other debris accumu late ...

Page 7: ...censed to do so Consult with your dealer for electrical work and grounding work Use a dedicated circuit for the air conditioner Pay Attention to Operating Sound Be sure to use the following places a Places that can sufficiently withstand the weight of the air conditioner and suppress the operat ing sound and vibration of the air conditioner b Places where warm air from the air outlet of the outdoo...

Page 8: ...nspection test operation When the inspection test operation button is pressed the display shows the mode in which the system actually is 10 Display under centralized control When this display shows the system is under centralized control This is not a standard spec ification 11 Display fan speed This display shows the fan speed you have selected 12 Display time to clean air filter Refer to the ope...

Page 9: ... outdoor temperature is 21 C or over 6 OPERATION PROCEDURE Operation procedure varies according to the com bination of outdoor unit and remote controller Read the chapter What to do before operation To protect the unit turn on the main power switch 6 hours before operation And do not turn off the power supply during the air conditioning season because of smoothly start up If the main power supply ...

Page 10: ...outdoor unit heat exchanger increases Heating capability decreases and the system goes into defrost operation The airflow will be set to breeze or stop If stopped the display of the remote control ler shows Once the airflow is set to breeze or stop the air conditioner will return to the previous state in approximately 10 to 15 minutes Hot start In order to prevent cold air from blowing out of an i...

Page 11: ...y swings as shown right and the air flow direction continuously varies Automatic swing setting Press the air flow direction adjust button to select the air direction of your choice The air flow flap display stops swing ing and the air flow direction is fixed Fixed air flow direction setting MOVEMENT OF THE AIR FLOW FLAP For the following conditions a micro computer con trols the air flow direction...

Page 12: ...OL HEAT Selector is connected to BS unit The COOL HEAT Selector can select opera tion mode Only the master remote controller can select heating cooling automatic operation The displays of slave remote controllers show changeover under control and they automatically follow the operation mode directed by the master remote controller However it is possible to changeover to program dry with slave remo...

Page 13: ...ilar equipment Failing to do so may cause static or distorted pic tures Turn off the main power supply switch to the unit when the unit is not used for longer periods of time If the switch is on it uses electricity Before restarting the unit turn on the main power supply switch 6 hours before operation to ensure smooth running Refer to the chapter Maintenance in the indoor unit manual Fully use th...

Page 14: ...communication between the units causing them to stop Operation automatically restarts when the noise goes away 9 3 COOL HEAT CANNOT BE CHANGED OVER When the display shows changeover under control It shows that this is a slave remote controller Refer to Setting the master remote controller When the cool heat selector switch is installed and the display shows changeover under control This is because...

Page 15: ...This is the sound of refrigerant gas flowing through both indoor and outdoor units A hissing sound which is heard at the start or immediately after stopping operation or defrost operation This is the noise of refrigerant caused by flow stop or flow change 9 9 DUST COMES OUT OF THE UNIT When the unit is used after stopping for a long time This is because dust has gotten into the unit 9 10 THE UNITS...

Page 16: ...e power on with the breaker switch in the trip position Contact your dealer 2 If the system stops soon after starting the opera tion Check if air inlet or outlet of outdoor or indoor unit is not blocked by obstacles Remove any obstacle and make it well ventilated Check if the remote controller display shows time to clean the air filter Refer to the operation manual of the indoor unit And clean the...

Page 17: ...oduct is assumed to be 10 hours day 2500 hours year Table 1 Inspection Cycle and Maintenance Cycle Lists Note 1 This table indicates main parts See the maintenance and inspection contract for details Note 2 This maintenance cycle indicates recommended lengths of time until the need arises for maintenance work in order to ensure the product is operational as long as possible Use for appropriate mai...

Page 18: ...efrigerant Contact your dealer for discarding the system air conditioner since it is required by law to collect transport and discard the refrigerant in accor dance with relevant local and national regulations Where to call For after sales service etc consult with your dealer Warranty period This product includes a warranty card The warranty card is given to a customer after dealer staff fills out...

Page 19: ...3P201178 2B EM07A012 0705 HT ...