BEA hereby declares that the IXIO-DT3 is in conformity with the basic requirements and the other relevant provisions of the directives 
1999/5/EC and 2006/42/EC.
Notified Body for EC-type inspection: 0044 - TÜV NORD CERT GmbH, Langemarckstr. 20, D-45141 Essen
EC-type examination certificate number: 44 205 12 405836-001
Angleur, June 2013 

Pierre Gardier, authorized representative and responsible for technical documentation

The complete declaration of conformity is available on our website: www.bea-pedestrian.be

Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment (WEEE)

TECHNICAL SPECIFICATIONS

Supply voltage:
Power consumption:
Mounting height:
Temperature range:
Degree of protection:
Noise:
Expected lifetime:
Applicable directives:

Presence

Typical response time: < 200 ms (max. 500 ms)

Active infrared with background analysis

Spot: 5 cm x 5 cm (typ)

Number of spots: max. 24 per curtain

Number of curtains: 2

Solid-state-relay 

(potential and polarity free)

Max. contact current: 100 mA

Max. contact voltage: 42 V AC/DC

Holdtime: 0.3 to 1 s

Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V)
Response time on test request: typical: < 5 ms

EN 12978 
EN ISO 13849-1:2008 PL «c» CAT. 2

(under the condition that the door control system 
monitors the sensor at least once per door cycle)

IEC 61496-1:2012 ESPE Type 2
EN 16005:2012 Chapter 4.6.8; 
DIN 18650-1:2010 Chapter 5.7.4
BS 7036-1:1996 Chapter 8.1

Motion

Min. detection speed: 5 cm/s

Microwave doppler radar

Transmitter frequency: 24.150 GHz

Transmitter radiated power: < 20 dBm EIRP

Transmitter power density: < 5 mW/cm

2

Solid-state-relay

(potential and polarity free)

Max. contact current: 100 mA

Max. contact voltage: 42 V AC/DC

Frequency output: 

Pulsed signal (f= 100 Hz +/- 10%) 

Current source output:

Galvanically isolated current source

No detection: current source ON

Open circuit voltage: 6.5 V

Output voltage available at 10 mA: 3 V min.

Typical load: up to 3 optocouplers in series

Detection: current source OFF

Open-circuit remained voltage: < 500 mV

EN 12978 
EN ISO 13849-1:2008 PL «d» CAT. 2
EN 16005:2012 Chapter 4.6.8; 
DIN 18650-1:2010 Chapter 5.7.4; AutSchR
BS 7036-1:1996 Chapter 7.3.2

(only applicable for frequency and current source 
output)

Detection mode:

Technology:

Output:

Test input:

Norm conformity:

Specifications are subject to changes without prior notice.
All values measured in specific conditions.

12 V - 24 V AC +/-10% ; 12 V - 30 V DC +/-10%  

(to be operated from SELV compatible power supplies only)

< 2.5 W
2 m to 3.5 m

 (local regulations may have an impact on the acceptable mounting height)

-25°C to +55°C; 0-95% relative humidity, non condensing
IP54
< 70 dB
20 years
R&TTE 1999/5/EC; MD 2006/42/EC; LVD 2006/95/EC; ROHS 2 2011/65/EU

PL

EA

SE

 K

EE

FO

FU

R

TH

ER

 U

SE

 - D

ES

IG

N

ED

 F

O

C

O

LO

U

PR

IN

TI

N

G

Содержание IXIO-DT3

Страница 1: ...d 3 radar antenna wide field 4 AIR curtain width adjustment 5 AIR lenses DESCRIPTION 6 cover 7 main connector 8 main adjustment knob 9 AIR curtain angle adjustment knob ENGLISH Opening safety sensor for automatic sliding doors User s Guide for product version 0300 and higher See product label for serial number ACCESSORIES BA Bracket Accessory CA Ceiling Accessory Retrofit interface according to EN...

Страница 2: ...ity 2 field size 9 immunity 2 The size of the detection field varies according to the mounting height of the sensor In emergency exits the full door width must be covered GREEN BROWN YELLOW WHITE PINK GREY RED BLUE YE BK WH BK POWER SUPPLY OPENING INPUT SAFETY INPUT TEST OUTPUT OPENING INPUT FOR EMEGENCY EXITS Output status when sensor is operational For compliance with EN 16005 and DIN 18650 conn...

Страница 3: ...ain of the inside door sensor and the inner curtain of the outside door sensor should always be smaller than 20 cm The distance to the door leaf depends therefore on the thickness of the door leaf The size of the detection field varies according to the mounting height and the settings of the sensor The full door width must be covered IMPORTANT Step out of the detection field before launching a set...

Страница 4: ...gs diagnostics Negative display active output displayed value saved value Select your language before entering the first LCD menu During the first 30 seconds after power on of the sensor or later in the diagnostics menu displayed value factory value CHANGING A VALUE scroll VALUES up down PUSH TO SAVE NEW VALUE VALUE CHECK WITH REMOTE CONTROL Display during normal functioning FACTORY VALUE VS SAVED...

Страница 5: ...d presence factory values small large bi uni uni AWAY low 0 5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s uni PRM bi auto uni auto PRM auto PRM for persons with reduced mobility AWAY unidirectional motion away from sensor auto automatic adaptation of field size small shops service mode motion 15 s 30 s 1 min 2 min 5 min 10 min motion motion or presence motion and presence opening output is active in cas...

Страница 6: ...e sensor Check the angle of the AIR curtains Launch a new assisted setup Attention Do not stand in the detection field Check output configuration setting Check wiring Check if the sensor is fastened firmly Check position of cable and cover Increase the AIR immunity filter to value 3 Select presetting 2 or 3 Select presetting 2 or 3 Increase radar immunity filter Change radar field angle Check if t...

Страница 7: ...r of the sensor The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor Only trained and qualifie...

Страница 8: ...O 13849 1 2008 PL c CAT 2 under the condition that the door control system monitors the sensor at least once per door cycle IEC 61496 1 2012 ESPE Type 2 EN 16005 2012 Chapter 4 6 8 DIN 18650 1 2010 Chapter 5 7 4 BS 7036 1 1996 Chapter 8 1 Motion Min detection speed 5 cm s Microwave doppler radar Transmitter frequency 24 150 GHz Transmitter radiated power 20 dBm EIRP Transmitter power density 5 mW ...

Отзывы: