4
6
+
5
3
DIN 18650
BS 7036
EN 16005
3,50 m
3 m
2,50 m
2 m
d max = 2,5 m
d max = 3 m
3,50 m
3 m
2,50 m
2 m
max.
9 cm**
OR
WIDTH
TIP!
Additional
adjustments
are possible by
LCD or remote
control
(see p. 5)
Part of the emitted field can be masked to reduce the detection field.
The arrow position determines the width of the detection field.
PUSH
2X
INFRARED SAFETY FIELD
CLOSER
AWAY
If necessary, adjust the AIR-curtain
angle (from -7° to 4°).
Activate the visible spots.*
ANGLE
SEtup 1 (quIck) =
SEtup 2 (ASSIStED) =
SETUP
OPEN+CLOSE
OR
IMPORTANT!
Test the good functioning of the installation before leaving the premises.
LONG PUSH (2 s)
SETTINGS
* Visibility depends on external conditions. When spots are not visible, use the Spotfinder to locate the curtains.
** The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should
always be smaller than 20 cm. The distance to the door leaf depends therefore on the thickness of the door leaf.
The size of the detection field varies according to the
mounting height and the settings of the sensor.
The full door width must be covered.
IMPORTANT!
Step out of the detection field before launching a setup.
OR
STANDARD:
inside installations
CRITICAL ENvIRONMENT:
critical or outside installations
SHOPPING STREET:
installations in narrow streets with pedestrian traffic
Mounting
height
Detection
width
2.00 m
2.20 m
2.50 m
3.00 m
3.50 m
2.00 m
2.20 m
2.50 m
d max
d max
Adjust the sensor by LCD or remote control (see p. 4 and 5)
or choose one of the presettings:
Always verify the actual detection field width
with a piece of paper and not the Spotfinder,
which detects the whole emitted field.
3.50 m
3 m
2.50 m
2 m
d max = 2.5 m
3.50 m
3 m
2.50 m
2 m
LONG PUSH (4 s)
DOOR
OR