E1

E2

E4

E5

E6

E7

E8

E9

TROUBLESHOOTING

The ORANGE LED 
flashes 1 x.

The ORANGE LED 
flashes 2 x.

The ORANGE LED 
flashes 4 x.

The ORANGE LED 
is on.

The RED LED flashes 
quickly after an 
assisted setup.

The RED LED 
lights up 
sporadically.

The GREEN LED 
lights up 
sporadically.

The LED and the 
LCD-display are off.

The reaction of 

the door does not 

correspond to the 

LED-signal.

The sensor signals 
an internal fault.

The power supply is too 
low or too high.

The sensor receives 
not enough AIR-energy.

The sensor encounters 
a memory problem.

The sensor vibrates.

The sensor sees the door 
during the assisted setup.

The sensor sees the door.

The sensor is disturbed 
by external conditions.

The sensor is disturbed by 
rain and/or leaves.

The sensor vibrates.

Ghosting created by door 
movement.

The sensor sees the door 
or other moving objects.

Check power supply 

(in the diagnostics menu of the LCD).

Check wiring.

Check the angle of the AIR-curtains.
Increase the AIR-immunity filter (values >2.8 m).

Cut and restore power supply.  
If orange LED lights up again, replace sensor.

Check the angle of the AIR-curtains.
Launch a new assisted setup.

Attention: Do not stand in the detection field!

Check output configuration setting.
Check wiring.

Check if the sensor is fastened firmly.
Check position of cable and cover.

Increase the AIR-immunity filter to value 3.
Select presetting 2 or 3.

Select presetting 2 or 3. 
Increase radar-immunity filter.

Change radar field angle.

Check if the sensor and door cover is fastened firmly.
Check position of cable and cover.

Change radar field size or angle.

Remove the objects if possible.

Launch an assisted setup and adjust the AIR angle.

Cut and restore power supply.
If orange LED flashes again, replace sensor.

The ORANGE LED 
flashes 6 x.

The ORANGE LED 
flashes 7 x.

The radar sensor output is 
faulty.

Replace sensor.

The internal test of the 
radar is disturbed.

Change radar field angle.
If orange LED flashes again, replace sensor.

Cut and restore power supply.
Check wiring.

The ORANGE LED 
flashes 5 x.

The sensor receives 
too much AIR-energy.

Check the angle of the AIR-curtains.
Decrease the AIR-immunity filter (values 1-3 <2.8 m).

Motion 
detection

Presence 
detection

LED flashes

LED flashes 
quickly

LED is off

The ORANGE LED 
flashes 8 x.

The AIR power emitter is 
faulty.

Replace sensor.

The ORANGE LED 
flashes 9 x.

The internal reference of 
the radar is faulty.

Replace sensor.

Содержание IXIO-DT3

Страница 1: ...d 3 radar antenna wide field 4 AIR curtain width adjustment 5 AIR lenses DESCRIPTION 6 cover 7 main connector 8 main adjustment knob 9 AIR curtain angle adjustment knob ENGLISH Opening safety sensor for automatic sliding doors User s Guide for product version 0300 and higher See product label for serial number ACCESSORIES BA Bracket Accessory CA Ceiling Accessory Retrofit interface according to EN...

Страница 2: ...ity 2 field size 9 immunity 2 The size of the detection field varies according to the mounting height of the sensor In emergency exits the full door width must be covered GREEN BROWN YELLOW WHITE PINK GREY RED BLUE YE BK WH BK POWER SUPPLY OPENING INPUT SAFETY INPUT TEST OUTPUT OPENING INPUT FOR EMEGENCY EXITS Output status when sensor is operational For compliance with EN 16005 and DIN 18650 conn...

Страница 3: ...ain of the inside door sensor and the inner curtain of the outside door sensor should always be smaller than 20 cm The distance to the door leaf depends therefore on the thickness of the door leaf The size of the detection field varies according to the mounting height and the settings of the sensor The full door width must be covered IMPORTANT Step out of the detection field before launching a set...

Страница 4: ...gs diagnostics Negative display active output displayed value saved value Select your language before entering the first LCD menu During the first 30 seconds after power on of the sensor or later in the diagnostics menu displayed value factory value CHANGING A VALUE scroll VALUES up down PUSH TO SAVE NEW VALUE VALUE CHECK WITH REMOTE CONTROL Display during normal functioning FACTORY VALUE VS SAVED...

Страница 5: ...d presence factory values small large bi uni uni AWAY low 0 5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s uni PRM bi auto uni auto PRM auto PRM for persons with reduced mobility AWAY unidirectional motion away from sensor auto automatic adaptation of field size small shops service mode motion 15 s 30 s 1 min 2 min 5 min 10 min motion motion or presence motion and presence opening output is active in cas...

Страница 6: ...e sensor Check the angle of the AIR curtains Launch a new assisted setup Attention Do not stand in the detection field Check output configuration setting Check wiring Check if the sensor is fastened firmly Check position of cable and cover Increase the AIR immunity filter to value 3 Select presetting 2 or 3 Select presetting 2 or 3 Increase radar immunity filter Change radar field angle Check if t...

Страница 7: ...r of the sensor The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor Only trained and qualifie...

Страница 8: ...O 13849 1 2008 PL c CAT 2 under the condition that the door control system monitors the sensor at least once per door cycle IEC 61496 1 2012 ESPE Type 2 EN 16005 2012 Chapter 4 6 8 DIN 18650 1 2010 Chapter 5 7 4 BS 7036 1 1996 Chapter 8 1 Motion Min detection speed 5 cm s Microwave doppler radar Transmitter frequency 24 150 GHz Transmitter radiated power 20 dBm EIRP Transmitter power density 5 mW ...

Отзывы: