BEA IXIO-DT3 Скачать руководство пользователя страница 5

off

1 s

2 s

3 s

4 s

5 s

6 s

7 s

8 s

9 s

>

>

>

>

>

>

>

>

>

>

1

2

A

B

>

>

>

+

 0       1        2        3         4 

  5        6        7 

8        9 

5

radar

off

OvERvIEW OF SETTINGS

Back
More

RAD: IMMUNITY

RAD: DIRECTION

RAD: HOLDTIME

AIR: WIDTH

AIR: NUMBER

AIR: PRESTIME

AIR: OUTPUT

REDIRECTION

FACTORYRST

DOOR BELL
More
Back

 

Back
More

PRESETTINGS

RAD: FIELDSIzE

RAD: OUTPUTAIR 

IMMUNITY

AIR: FREq

More
Back

zIP 

             

all parameter settings in zipped format 

ID # 

             

unique ID-number 

ERROR LOG             

the last 10 errors

AIR: SPOTVIEW       

view of spot(s) that trigger detection

AIR: C1 ENERG        

signal amplitude received on curtain 1

AIR: C2 ENERG        

signal amplitude received on curtain 2

POWERSUPPLY 

supply voltage at power connector

OPERATINGTIME 

power duration since first startup

RESET LOG 

 

delete all saved errors

RC PASSWORD 

password for remotre control login

LANGUAGE 

language of LCD-menu

ADMIN  

enter code to access admin mode

standard critical

env.

shopping 

street

For conformity to EN 16005 or DIN 18650 at a 

mounting height of 2.8 or more, use values 6 and 7. 

For conformity to BS 7036 at a mounting height 

of 2.2 m or more, use values 6 and 7.

Sensors mounted close to each other should 
have a different frequency.

increased immu 1 curtain
increased immu redirection = motion and presence

factory values

small

large

bi

uni

uni

AWAY

low

0.5 s

1 s

2 s

3 s

4 s

5 s

6 s

7 s

8 s

9 s

uni 

PRM

bi

auto

uni

auto

PRM

auto

PRM: for persons with reduced mobility

AWAY: unidirectional motion away from sensor

auto: automatic adaptation of field size (small shops)

service

mode

motion 15 s

30 s

min

min

min

10 

min

motion

motion

or

presence

motion

and

presence

opening output is active in case of:   0   motion detection

 

 

     1   motion 

or

 presence detection

 

 

     2   motion 

and

 presence detection

20 min 60 min infinite

service mode = no IR detection during 15 minutes (maintenance).
This value excludes conformity of the door system to EN 16005 and DIN 18650.

high

restore to factory values

min. value for DIN18650: 1 min
min. value for EN16005: 30 s

IMPORTANT!

The auto mode of the detection direction is not allowed 
when the sensor is used in emergency exits.

BASIC

ADV

ANCED

DIAGNOSTICS

freq: frequency output

current: current output

NO: normally open

NC: normally closed

Always additionally adjust 
the arrow position on the 
sensor with a screwdriver.

excludes conformity to EN 16005 / DIN 18650 / BS 7036 of the door system

freq

NC

current

NC

NO

NC

NC

NC

NC

NO

NO

NO

freq

NC

current

NC

NO

NC

NC

NC

NC

NO

NO

NO

freq: frequency output

current: current output

NO: normally open

NC: normally closed

see application note DOOR 

BELL for more information

low

normal

high

normal

high

higher highest

< 2.8 m

> 2.8 m

Содержание IXIO-DT3

Страница 1: ...d 3 radar antenna wide field 4 AIR curtain width adjustment 5 AIR lenses DESCRIPTION 6 cover 7 main connector 8 main adjustment knob 9 AIR curtain angle adjustment knob ENGLISH Opening safety sensor for automatic sliding doors User s Guide for product version 0300 and higher See product label for serial number ACCESSORIES BA Bracket Accessory CA Ceiling Accessory Retrofit interface according to EN...

Страница 2: ...ity 2 field size 9 immunity 2 The size of the detection field varies according to the mounting height of the sensor In emergency exits the full door width must be covered GREEN BROWN YELLOW WHITE PINK GREY RED BLUE YE BK WH BK POWER SUPPLY OPENING INPUT SAFETY INPUT TEST OUTPUT OPENING INPUT FOR EMEGENCY EXITS Output status when sensor is operational For compliance with EN 16005 and DIN 18650 conn...

Страница 3: ...ain of the inside door sensor and the inner curtain of the outside door sensor should always be smaller than 20 cm The distance to the door leaf depends therefore on the thickness of the door leaf The size of the detection field varies according to the mounting height and the settings of the sensor The full door width must be covered IMPORTANT Step out of the detection field before launching a set...

Страница 4: ...gs diagnostics Negative display active output displayed value saved value Select your language before entering the first LCD menu During the first 30 seconds after power on of the sensor or later in the diagnostics menu displayed value factory value CHANGING A VALUE scroll VALUES up down PUSH TO SAVE NEW VALUE VALUE CHECK WITH REMOTE CONTROL Display during normal functioning FACTORY VALUE VS SAVED...

Страница 5: ...d presence factory values small large bi uni uni AWAY low 0 5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s uni PRM bi auto uni auto PRM auto PRM for persons with reduced mobility AWAY unidirectional motion away from sensor auto automatic adaptation of field size small shops service mode motion 15 s 30 s 1 min 2 min 5 min 10 min motion motion or presence motion and presence opening output is active in cas...

Страница 6: ...e sensor Check the angle of the AIR curtains Launch a new assisted setup Attention Do not stand in the detection field Check output configuration setting Check wiring Check if the sensor is fastened firmly Check position of cable and cover Increase the AIR immunity filter to value 3 Select presetting 2 or 3 Select presetting 2 or 3 Increase radar immunity filter Change radar field angle Check if t...

Страница 7: ...r of the sensor The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor Only trained and qualifie...

Страница 8: ...O 13849 1 2008 PL c CAT 2 under the condition that the door control system monitors the sensor at least once per door cycle IEC 61496 1 2012 ESPE Type 2 EN 16005 2012 Chapter 4 6 8 DIN 18650 1 2010 Chapter 5 7 4 BS 7036 1 1996 Chapter 8 1 Motion Min detection speed 5 cm s Microwave doppler radar Transmitter frequency 24 150 GHz Transmitter radiated power 20 dBm EIRP Transmitter power density 5 mW ...

Отзывы: