OVERVIEW OF SETTINGS

Back
More

RAD: FIELDSIZE

AIR: WIDTH

AIR: OUTPUT

TEST

More
Back

ZIP CODE         

all parameter settings in zipped format

 

        

(see application note on ZIP CODE 

 76.0024)

ID # 

       

unique ID-number

CONFIG P/N
SOFT P/N
ERROR LOG        

last 10 day indication

AIR: SPOTVIEW  

view of spot(s) that trigger detection

AIR: C1 ENERG       

signal amplitude received on curtain 1

AIR: C2 ENERG       

signal amplitude received on curtain 2

POWERSUPPLY       

supply voltage at power connector

OPERATINGTIME    

power duration since first startup

RESET LOG 

           delete all saved errors

PASSWORD            

LCD and remote control password

 

           (0000= no password)

ADMIN 

           

enter code to access admin mode

opening output is active in case of:

0   motion detection
1   motion 

or

 presence detection

2   motion 

and

 presence detection

min. value for DIN18650:  1 min

min. value for EN16005:    30 s

BASIC

ADV

ANCED

DIAGNOSTICS

partial: outputs are not reset

factory value

Always additionally adjust the 

arrow position on the sensor with a 

screwdriver.

Always additionally adjust the 

arrow position on the sensor with a 

screwdriver.

small

small

small

normal

0.5 s

DeEner: De-Energized relay

Energ: Energized relay

NO: normally open

NC: normally closed

DeEner: De-Energized relay

Energ: Energized relay

NO: normally open

NC: normally closed

DeEner: De-Energized relay

Energ: Energized relay

NO: normally open

NC: normally closed

>

>

>

8 s

60 min

full 

reset

>

large

large

large

9 s

infinte

partial 

reset

high

>

>

>

6 s

10 min

>

>

>

>

mode B

7 s

20 min

>

>

>

>

5 s

5 min

>

>

>

>

4 s

2 min

>

uni

MTF

>

>

>

3 s

1 min

>

uni

>

>

>

enhanced

1 s

1

A

low

off

>

>

>

2 s

30 s

2

B

>

bi

0

1

2

3

4

5

6

7

8

9

on

on

motion

or

presence

off

off

motion

The sensor LED will briefly flash RED during monitoring communication with door control.  

This indicates that external monitoring is functional. 

Monitoring functionality must be active on the sensor and monitoring wires must be properly connected to the door control.

The sensor LED will briefly flash RED during monitoring communication with door control.  

This indicates that external monitoring is functional. 

Monitoring functionality must be active on the sensor and monitoring wires must be properly connected to the door control.

MTF: motion tracking feature

Содержание IXIO-DT1

Страница 1: ...connector 8 main adjustment knob 9 AIR curtain angle adjustment knob Activation safety sensor for automatic sliding doors 10IMB Bracket accessory 10ICA Ceiling accessory 10CDA Curved door accessory 10IRA Rain accessory Download the BEA DECODER app for a quick overview of settings ENGLISH 35 1286 black cover 35 1302 white cover 35 1303 silver cover 10IXIOSPACER Spacer DESCRIPTION ACCESSORIES ...

Страница 2: ...ned and qualified personnel are recommended for installation and set up of the sensor The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel Following installation always test for proper operation according to ANSI 156 10 before leaving the premises The door control unit and the header cover profile must be correctly grounded SAFETY It is recommended to cle...

Страница 3: ...played more values are displayed current value is displayed displayed value saved value displayed value factory value Activation impulse Safety 6 6 CHANGING A ZIP CODE Enter password if necessary Not during the first minute after power on of the sensor Password X X X X ZIP code V Validate the last digit in order to activate the new ZIP code v valid ZIP code values will be changed accordingly x inv...

Страница 4: ...s must be properly connected to the door control max 2 in Sensor connectivity power and relays must utilize only the supplied harness Sensor power must be supplied from a Class 2 supply source limited to 15 W Sensor is intended to be monitored for proper operation by the door operator or system Harness shall be routed separated from any Mains or non Class 2 voltage cable for correct operation or s...

Страница 5: ...eld width by walk testing according to ANSI 156 10 guidance DOOR max 3 in Mounting height Detection width 6 6 7 3 16 8 3 16 9 13 16 11 6 6 6 7 3 16 8 3 16 9 13 16 11 6 Additional adjustments are possible by LCD or remote control see OVERVIEW OF SETTINGS Visibility depends on external conditions When spots are not visible use the Spotfinder to locate the curtains The distance between the inner curt...

Страница 6: ...tion and presence detection min value for DIN18650 1 min min value for EN16005 30 s BASIC ADVANCED DIAGNOSTICS partial outputs are not reset factory value Always additionally adjust the arrow position on the sensor with a screwdriver Always additionally adjust the arrow position on the sensor with a screwdriver small small small normal 0 5 s DeEner De Energized relay Energ Energized relay NO norma...

Страница 7: ...replace the sensor RED LED flashes quickly after an assissted set up The sensor sees the door during assissted set up Move the AIR curtains away from the door Install the sensor as close to the door as possible If needed use a bracket assembly Ensure that the bottom of the sensor is mounted within 2 of the bottom of the door header Launch a new assisted set up RED LED illuminates sporadically The ...

Страница 8: ...perly connected to the door control Verify monitoring TEST is on in the sensor settings Sensor and or wiring malfunction Verify that there are no breaks anywhere in the wire harness Replace the sensor Visible External Monitoring Test Indication LED red flashes continuously Wiring issue Verify wiring Control not set correctly Verify control monitoring set to Active Low Door cycles open and remains ...

Страница 9: ... DASMA guidelines where applicable for best industry practices Safety inspections must be performed during each service call examples of these safety inspections can be found on an AAADM safety information label e g ANSI DASMA 102 ANSI DASMA 107 UL 325 Verify that all appropriate industry signage and warning labels are in place BEA INSTALLATION SERVICE COMPLIANCE EXPECTATIONS Supply voltage 12 24 ...

Страница 10: ...FRANÇAIS DESCRIPTION 1 écran ACL 2 réglage de la largeur du rideau IRA 3 lentilles IRA 4 capot 5 connecteur principal 6 bouton de réglage principal 7 bouton de réglage de l angle du rideau IRA 10IMB accessoire de support 10ICA accessoire de plafond 10CDA accessoire pour porte courbée 10IRA accessoire anti pluie 35 1286 couvercle noir 35 1302 couvercle blanc 35 1303 couvercle argent 10IXIOSPACER ac...

Страница 11: ...ière dans le champ de détection Ne couvrez pas le détecteur Nous recommandons de nettoyer les pièces optiques au moins une fois par an ou plus le cas échéant en raison des conditions environnementales N utilisez pas de produits agressifs pour nettoyer les pièces optiques ENTRETIEN SÉCURITÉ Confiez l installation et la configuration du détecteur uniquement à du personnel formé et qualifié La garant...

Страница 12: ...tout en le tournant Lors du fonctionnement normal seulement Affichage négatif entrée active Impulsion d activation Sécurité Appuyez sur le bouton pour sélectionner un para mètre Faites défiler le menu vers le haut vers le bas CHANGER UNE VALEUR Faites défiler les valeurs vers le haut vers le bas Appuyez sur le bouton pour enregis trer la nouvelle valeur Code ZIP une nouvelle valeur est affichée pl...

Страница 13: ... nationaux et locaux pour éviter d endommager le faisceau Le montage est compatible avec WIZARD PLUS PROCHE PLUS LOIN ANGLE OU Activez les points visibles pour vérifier la position du rideau IRA En cas de besoin réglez l angle du rideau IRA de 7 à 4 0º par défaut max 3 po PORTE La visibilité dépend des conditions externes Lorsque les points ne sont pas visibles utilisez le dispositif Spotfinder po...

Страница 14: ...ation au connecteur d alimentation DURÉE DE FONCTIONNEMENT durée de fonctionnement depuis le démarrage initial RÉINITIALISATION JOURNAL supprimez toutes les erreurs enregistrées MOT DE PASSE mot de passe de l écran ACL et de la télécommande 0000 aucun mot de passe ADMIN saisissez un code pour accéder au mode d admin AVANCÉS 0 5 s Désexcité NO Excité NF Désexcité NO Excité NF Excité NF Excité NF Ex...

Страница 15: ... détecteur rencontre un problème de mémoire Coupez l alimentation électrique puis rétablissez la Si le voyant DEL ORANGE s allume de nouveau remplacez le détecteur Le voyant DEL ROUGE clignote rapidement après la configuration assistée Le détecteur détecte la porte lors de la configuration assistée Éloignez les rideaux IRA de la porte Installez le détecteur aussi près que possible de la porte Au b...

Страница 16: ...able de surveiller et que les fils de surveillance du détecteur sont correctement connectés au dispositif de commande de la porte Vérifiez que la surveillance TEST est activée dans les réglages du détecteur Dysfonctionnement du détecteur et ou du câblage Vérifiez qu il n y a pas de rupture dans le faisceau de câblage Remplacez le détecteur Le voyant DEL rouge de surveillance test externe clignote ...

Страница 17: ...ecteur ne peut pas être tenue responsable pour des installations incorrectes ou des ajustements inappropriés du détecteur de l appareil par conséquent BEA ne garantit aucun usage du capteur en dehors de son but prévu BEA recommande fortement que les techniciens d installation et de services soient certifiés AAADM pour les portes piétonnières certifiés IDA pour les portes portails et formés en usin...

Отзывы: