![BEA IXIO-DT1 Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/bea/ixio-dt1/ixio-dt1_manual_2715840004.webp)
Page 4 of 9
75.5751.11 IXIO-DT1 UL 20180305
2
1
7.2 ft
7.2 ft
RADAR OPENING IMPULSE FIELD
ANGLE
field size: 9
immunity: 2
field size: 9
immunity: 2
The size of the detection field varies according to the mounting height of the sensor.
The following graphics are representations - not default settings.
from 15° to 45°, default 30 °
from -15° to 15°, default 0°
7.2 ft
7.2 ft
WID
TH
13’ x 6’6" (wide)
6’6" x 8’ (narrow)
field size: 9
immunity: 2
field size: 9
immunity: 2
1 × 1 grid is approximately 3.28 ft × 3.28 ft.
MOUNTING & WIRING
Mounting is compatible with the WIZARD.
* Output status when sensor is operational.
** The sensor LED will briefly flash RED during monitoring communinication
with door control. This indicates that external monitoring is functional.
Monitoring functionality must be active on the sensor and monitoring
wires must be properly connected to the door control.
max. 2 in
Sensor connectivity (power and relays) must utilize only the supplied harness.
Sensor power must be supplied from a Class 2 supply source limited to 15 W.
Sensor is intended to be monitored for proper operation by the door operator or system.
Harness shall be routed separated from any Mains or non-Class 2 voltage cable for correct operation or shall be rated for the Mains
voltage, and suitable protection and routing means shall be used according to National and Local Codes to prevent damage to the harness.
Use the provided mounting template and mount the sensor, ensuring that the bottom of the sensor is within 2
inches of the bottom of the door header.
Route the harness using the harness clip as shown in the exploded view of the mounting illustration.
12-24 V AC, 50/60 Hz
12-30 V DC
Max 2.5 W
12-24 V AC, 50/60 Hz
12-30 V DC
Max 2.5 W
RED
BLACK
POWER SUPPLY
SAFETY INPUT
OPENING INPUT
TEST OUTPUT**
BROWN
BLUE
WHITE
YELLOW
GREEN
PURPLE
PURPLE