16

17

Before starting the engine, do not connect 

any electric devices.

Turn the ESC switch to “OFF” (1)

Turn the 3 in 1 switch to “CHOKE”

a. Ignition circuit is switched on.

b. Fuel is switched on.

c. Choke is switched off.

TIP:

 The choke is not required to start a 

warm engine. Push the choke knob in to the

position “ON”.

TIP:

• The generator can be used with the rated output load at standard 

atmospheric conditions.

• “Standard atmospheric conditions ”; Ambient temperature 25.

• Barometric pressure 100kPa; Relative humidity 30%

• The output of the generator varies due to change temperature, altitude 

(lower air pressure at higher altitude) and humidity.

• The output of the generator is reduced when the temperature, the 

humidity and the altitude are higher than standard atmospheric 

conditions.

• Additionally, the load must be reduced when using in confined areas, as 

generator cooling is affected.

STARTING THE ENGINE

Operation

NOTICE

• Never operate the engine in a closed area or it may cause uncon-

sciousness and death within a short time. Operate the engine in a well 

ventilated area. The generator has been shipped without engine oil. 

Do not start the engine until filled with the sufficient engine oil.

Electric Start

Turn the engine switch on the control panel 

to ON Or press it to START if it is electrical 

start state then generator unit can be 

started In order to extend the service life 

of the storage battery do not press on the 

switch for more than 3 seconds and the 

interval between two pressings should be 

longer than 10 seconds.

Recoil Start

Grasp the carrying handle firmly to prevent 

the generator from falling over when pulling 

the recoil starter.

After the engine starts, warm up the engine 

until the engine does not stop when the 

choke knob is returned to the “ON” position. 

(3)

TIP:

When starting the engine, with the ESC 

“ON” and there is no load on the generator:

In ambient temperature below 0ºC (32ºF), 

the engine will run at the rated (3600r/min) 

for 5 minutes to warm up the engine.

In ambient temperature below 5ºC (41ºF), 

the engine will run at the rated r/min (3600r/

min) for 3 minutes to warm up the engine.

The ESC unit operates normally after the 

above time period, while the ESC is “ON”.

Release the load.

STOP THE ENGINE

OPERATION

OPERATION

Содержание I3500L

Страница 1: ...Operation Manual I3500L INVERTER GENERATOR BEPOWEREQUIPMENT COM...

Страница 2: ...Operation 16 Operation 16 Staring the engine 17 Stopping the engine 18 Alternating Current AC connection 19 Battery Charging 20 AC Parallel Operation 21 AC Parallel Operation Applications 22 Applicati...

Страница 3: ...rator and should be read thoroughly before initial use and referred to often to make sure adequate safety and service concerns are being addressed Reading the owner s manual thoroughly will help avoid...

Страница 4: ...ding lines and plug connections should not be defective Utilize safe proper grounding Use the ground wire with enough electric flux Ground wire diameter 0 12mm A The generator surface has high tempera...

Страница 5: ...de colourless and odorless gas are produced during operation which may lead to suffocation Only use the generator in well ventilated areas Warning Dangerous voltages are present when the generator is...

Страница 6: ...umulative time current time In case of failed operation U a AC over voltage indicating the character of AC alternative indication of AC and digit b DC over voltage indicating the character of DC alter...

Страница 7: ...g air Inlet and around the control unit If any blockages are found remove them 4 After checking restart the engine TIP The overload indicator light may come on for a few seconds at first when using el...

Страница 8: ...ully before filling Do not overfill the fuel tank otherwise it may overflow when the fuel warms up and expands After filling the fuel make sure the fuel tank cap is tightened securely Immediately wipe...

Страница 9: ...Operate the engine in a well ventilated area The generator has been shipped without engine oil Do not start the engine until filled with the sufficient engine oil Electric Start Turn the engine switch...

Страница 10: ...s a short circuit in a connected appliance the overload indicator red will go ON The overload indicator red will stay ON and after about 4 seconds the connected appliance s will shut off and the outpu...

Страница 11: ...Flush with water INTERNAL Drink large quantities of water or milk Follow with milk of magnesia beaten egg or vegetable oil Call physician immediately EYES Flush with water for 15 minutes and get prom...

Страница 12: ...upply range of the generator Overloading will damage the generator When supplying precision equipment electronic controllers PCs electronic computers microcomputer based equipment or battery chargers...

Страница 13: ...necessary x Oil Check oil level in engine x x 1 Replace Air Filter Check condition Clean and replace if necessary x 2 Muffler Screen Check condition Clean and replace if necessary x Spark Arrester Che...

Страница 14: ...so properly CLEAN FUEL FILTER ENGINE OIL REPLACEMENT 1 Unscrew the screw 1 and take off the left exterior cover 2 2 Drain the fuel in the fuel tank Hold the tube clip 3 toward downward and pull out th...

Страница 15: ...tilt the generator when adding engine oil This could result in overfilling and damage to the engine Don t allow foreign objects to fall into engine Oil and gasoline could pollute the environment don t...

Страница 16: ...einstall the spark plug 2 Recoil start the engine by turning over several times with 3 in 1 switch knob off to coat the cylinder walls with oil 3 Pull the recoil starter until you feel compression Thi...

Страница 17: ...r Type Inverter Rated frequency Hz 60 Rated voltage v 120 Rated output power kW 3 0 Max output power kW 3 3 Power Factor 1 AC output quality ISO8528 G2 THD 5 Noise Level dB LpA LwA K 4m 1 4 load 60 DC...

Страница 18: ...34 If you need assistance with the assembly or operation of your Generator please call 1 866 850 6662 THE POWER YOU NEED...

Страница 19: ...Si vous avez besoin d aide avec l assemblage ou l utilisation de votre g n ratrice veuillez appeler au 1 866 850 6662 THE POWER YOU NEED...

Страница 20: ...ircuit breaker 20A circuit breaker 30A Voyant d avertissement du niveau d huile Voyant de surcharge Lampe t moin d alimentation lectrique Prise CC Disjoncteur 10A Disjoncteur 20A Disjoncteur30A Commut...

Страница 21: ...oteur et appliquer un additif anticorrosion 6 Ranger la g n ratrice dans un endroit sec et bien ventil avec son couvercle plac dessus 7 Mettre le moteur la verticale D pannage LE MOTEUR NE D MARRE PAS...

Страница 22: ...ge Effectuez les tapes suivantes pour prot ger le cylindre le segment de piston etc contre la corrosion 1 Retirez la bougie d allumage versez environ une cuill re soupe d huile SAE 10W 30 dans le trou...

Страница 23: ...s 1 et retirer le couvercle ext rieur gauche 2 2 Videz le carburant du r servoir de carburant Tenez l attache pour tube 3 vers le bas et sortez le tube de carburant 4 qui est connect sur le r servoir...

Страница 24: ...allumage doit tre serr e au couple sp cifi d s que possible 7 Remettez la t te de la bougie et le cou vercle de la bougie en place Le carburateur est une partie essentielle du moteur Son r glage doit...

Страница 25: ...lus importants de l inspection et de la lubrification de la g n ratrice sont expliqu s dans les pages suivantes AVERTISSEMENT Si vous n tes pas familier avec les travaux d entretien faites les effectu...

Страница 26: ...onctionner de mani re anormale lent ou s arr te soudainement vous devez l teindre imm diatement D connecter l appareil et d terminer si le probl me provient de l appareil et d terminer si le probl me...

Страница 27: ...RECHARGE DE LA BATTERIE CONSEIL La tension nominale du g n rateur CC est de 12 V Commencez par d marrer le moteur puis branchez le g n rateur la batterie pour la recharger Avant de commencer recharge...

Страница 28: ...ge Lors du d marrage d un moteur lectrique l indicateur de surcharge rouge peut s allumer C est normal si l indicateur de surcharge rouge s teint dans les 4 secondes Si 19 OP RATION D marrage lectriqu...

Страница 29: ...midit ou l altitude est sup rieure aux valeurs des conditions atmosph riques normales En outre la charge doit tre r duite lors de l utilisation dans un espace confin parce que le refroidissement du g...

Страница 30: ...ultez attentivement les Consignes de s curit avant de faire le plein Ne pas trop remplir le r servoir de carburant pour viter qu il ne d borde lorsque le carburant chauffe et se dilate Apr s avoir fai...

Страница 31: ...au d huile 1 s allume et le moteur s arr te automatiquement Le moteur ne pourra pas red marrer tant que vous n aurez pas ajout d huile CONSEIL Si le moteur cale ou ne d marre pas mettez le commutateur...

Страница 32: ...in d alimentation lectrique 11 FONCTION DE COMMANDE 1 Activ ON Lorsque l interrupteur ESC est mis sur D sactiv OFF le moteur fonctionne au r gime nominal 4500 tr min qu une charge soit branch e ou non...

Страница 33: ...e tincelle et cigarette Nettoyer tout d versement de carburant imm diatement teindre le moteur et le laisser refroidir avant de faire le plein de carburant de la g n ratrice Le carburant peut s enflam...

Страница 34: ...op ration s curitaire de la g n ratrice DANGER N utilisez jamais l appareil l int rieur DANGER Garder la machine propre et viter d y d verser des combustibles y compris de l essence AVERTISSEMENT Ne...

Страница 35: ...afin d viter des blessures ventuelles ou la mort explosion manations toxiques feu contre coups choc lectrique lisez le guide 5 R GLES DE S CURIT S Utilisation du guide de l utilisateur Le guide de l u...

Страница 36: ...n 5 Conservez ces consignes 6 Consignes de S curit Fonction de commande 9 Description 9 Panneau De Commande 10 Commutateur 3 En 1 10 Contr le Intelligent Du Moteur Esc 11 Affichage Num rique 12 Voyant...

Страница 37: ...Guide de l utilisateur G N RATRICE INVERSEUR I3500L BEPOWEREQUIPMENT COM...

Отзывы: