200646_01
13
21 SERVICE AND MAINTENANCE
WARNING.
This product uses fuel effect pieces containing Refractory Ceramic Fibre (RCF),
which are man-made vitreous silicate fibres along with fibrous glass and mineral
wool. Excessive exposure to these materials may cause temporary irritation to
eyes, skin and respiratory tract, consequently, it makes sense to take care when
handling these articles to ensure that the release of dust is kept to a minimum.
The appliance should be serviced at least once a year by a CORGI registered
engineer and recorded on the Installation & Service Record (see page 19). This is
the basic procedure.
1
BEFORE ANY SERVICING IS CARRIED OUT ENSURE THE GAS SUPPLY TO THE
APPLIANCE IS TURNED OFF AND THE ELECTRICAL SUPPLY IS ISOLATED.
AFTER REFITTING THE APPLIANCE, CHECK FOR GAS SOUNDNESS AND
SPILLAGE.
2
The coals / pebbles and ceramics should be taken off the fire and all unwanted debris
and soot removed from the ceramics and burners. This can be done by using a vacuum
cleaner. The burner ports should be thoroughly cleaned.
3
The coals / pebbles must be treated gently. Remove each one by hand and clean with a
soft brush.
4
Badly damaged coals / pebbles should be replaced. Replacement fuel pieces are
available from our stockists.
5
Check that there is no impairment to the electrode spark or pilot burner.
6
Check that the pilot flame is satisfactory. If it is not, remove and clean the pilot injector.
7
Rebuild the fuel lay as described in Section 13.
8
Make final adjustment to coals / pebbles to obtain a satisfactory visual effect.
9
Remove the cover from the fan box, disconnect the electrical connections and remove
the fan carrier. Clear the blades of any soot or debris.
10
Refit the fan carrier, reconnect the electrical supply and refit the cover.
11
Reseal the cover as previously described.
AFTER REFITTING THE APPLIANCE CHECK FOR GAS SOUNDNESS AT ALL GAS
JOINTS AND TEST FOR SPILLAGE.
12
The service record sheet enclosed with these instructions should be completed to maintain
the validity of the guarantee.
22
Spare Part List
Manual low level Control
V4-16
V4-16A
SOV/SHH/003
OP 9017
OP 9214
Part Description
Gas valve (NG models)
Gas valve (LPG models)
Solenoid valve
Oxypilot (NG models)
Oxypilot (LPG models)
Base & Rear Ceramic
Large Coals*
Medium Coals *
Medium Random Coals*
Large Pebbles*
Small Pebbles*
Drg Nos.10168 / 10155 / Supplier Ref. CR1851
CR0071
CR0010
CR0003/R1
CR0098 (Grey or Fawn)
CR0098 (Grey or Fawn)
* See Page 3 for quantities required