• The appliance must be installed in a room without sources of
ignition (for example: open flames, an operating gas
appliance or an operating electric heater).
• The unit must be installed on a solid vertical wall by a
competent person. The electricity supply must only be
connected after installation is complete.
• R290 refrigerant gas complies with European
environmental directives.
• R290 has a low GWP (Global Warming Potential) of 3.
• The air conditioner contains about 290 g of
R290 refrigerant gas.
• Do not install or store in an unventilated space with an area
smaller than 15 m2 per unit. The room must be such as to
prevent stagnation of possible leaks of refrigerant gas as
there could be a danger of fire or explosion hazard should the
refrigerant come into contact with electric heaters, stoves or
other sources of ignition.
• If the appliance is installed, used or stored in an unventilated
room, the room must be such as to prevent stagnation of
possible leaks of refrigerant gas as there could be a danger
of fire or explosion should the refrigerant come into contact
with electric heaters, stoves or other sources of ignition.
• Refrigerant gas may be odourless.
• Do not use the product and contact the retailer for
advice, if damage has occurred to the unit which may
have compromised the refrigerant system.
Содержание BC10MBKL2101F
Страница 1: ...MONOBLOCK KLIMAGER T BC10MBKL2101F AIR CONDITIONER BC10MBKL2101F GEBRAUCHSANWEISUNG OPERATOR S MANUAL...
Страница 32: ...TECHNISCHE ZEICHNUNG MODELL BC10MBKL2101F...
Страница 35: ...34 35 D...
Страница 66: ...TECHNICAL DRAWING MODEL BC10MBKL2101F...
Страница 69: ...68 69 E...
Страница 70: ...NOTE...
Страница 71: ...70 71 E NOTE...
Страница 72: ...Schuss Home Electronic GmbH Scheringgasse 3 A 1140 Wien Tel 43 1 97 0 21 0...