Use
Select the rotating speed range
(only MABasic 400, 450 and 850)
ATTENTION
►
Switch the gear stages only with the
machine at standstill.
NOTE
►
Select the speed range according to
the material and drilling diameter.
Select the gear stage MABasic 400/450
The machine has a gearbox with two me-
chanical gear stages. The rotation speeds
of the gear stages are specified in the
technical data.
To select the desired gear stage,
set selector lever on the gearbox (3)
to stage 1 or 2 with the machine
switched off.
Select the gear stage MABasic 850
The machine is equipped with a gearbox
that has four mechanical gear stages. The
rotation speeds of the gear stages are
specified in the technical data.
To select the gear stage, switch the
machine off and set both selector le
-
vers on the gearbox (3) to the desired
speed according to the table below.
Rotating
speed
Selector lever
left
right
Level 1
▼
▲
Level 2
▼
▼
Level 3
▲
▲
Level 4
▲
▼
Activating/deactivating the mag-
netic clamp
Activating the magnetic clamp
ATTENTION
►
To prevent the magnet from overheat-
ing, switch on the magnetic clamp
only when the machine is standing on
a magnetic substrate.
Turn on the switch (11). The indicator
lamp in the switch (11) lights up.
ATTENTION
►
The maximum magnetic holding
force is only available after
switching on the motor.
Deactivating the magnetic clamp
Hold the handle tightly (5) to stop the
machine from slipping.
Turn off the switch (11). The indicator
lamp in the switch (11) extinguishes.
Switching the machine ON/OFF
Using the ON/OFF switch (10), turn
the machine ON with the green button
(I) and OFF with the red button (O).
NOTE
►
The machine can only be switched on
when the magnetic clamp has been
switched on.
►
Allow a severely overheated machine
to run on at idle speed for approx.
2 minutes.
►
The machine switches off automati
-
cally in the event of a power failure or
if the magnetic clamp is switched off.
use