DISINFECTION EFFICIENCY
* The bactericidal efficiency is calculated by S. aureus.
* The air flow is 30 m/h
* The maximum volume (cubature) of the disinfected room: 50 m
3
Recommended floor
volume, m
3
99% for areas for
medical purpose,
labs etc
95,0 % for areas like
study or play rooms,
smoking room, public
toilets etc
Time of disinfection (min) with efficacy (*)
Up to 30
From 31 up to 50
AS8.1
60
45
80
60
2. Remove the pipe clips from the device and fix them
at the selected location with suitable screws and/or
plugs.
3. Place the UV HALO in the fixed pipe clips and screw
the brackets into place.
4. Insert the plug into the socket and check the
operation of the UV-C lamp – only do this through the
air vents at the top or bottom of the unit! Blue light
can be seen through the air vents of the lid if the lamp
is on.
5. Check the operation of the ventilator by holding
your hand on the top the unit grid. If you feel an air
flow, the ventilator is working.
6. Check if the display with countdown of UV-C lamp
lifetime is working – numbers on the display will
light on and will show 8000*. The UV HALO can be
set using the display on the front of the device. The
display easily operated with just the one button –
switch ON/OFF.
7. Switching off the device: it is not necessary to
switch off the device during the day because it has
been designed to operate 24 hours a day to avoid
the formation of new micro-organisms. You can
switch the device off by pressing ON/OFF button and
removing the plug from the socket.
INSTALLATION OF THE DEVICE
5
6
‘
8000.’: If you press the button once in the rest position, the operating
hours will be displayed. The display will automatically start from the
factory setting of the timer, i.e. 8,000 hours. The UV-C lamp operates
at 100% radiation for up to 8,000 hours. After 8,000 operating hours,
the UV-C radiation will weaken, and may be insufficient to obtain the
desired results. If the device is switched off and then on again, the hour
LAMP OPERATING TIME
*
The UV-C light emitted by the lamp is highly harmful
to humans and other living organisms, damages
eyesight, skin and cell DNA. UV-C light degrades the
DNA and RNA code in the cells of living organisms.
After starting the luminaire no people or animals
should be within the range of direct UVC rays.
Damage to the luminaire will not affect your health
while maintaining basic precautions. If the fluorescent
lamps break, ventilate the room for 30 minutes and
remove the contaminated parts, preferably with
gloves. Place them in a sealed plastic bag and take to
a local waste disposal facility for recycling. Do not use
a vacuum cleaner to remove damaged parts.
OPERATIONAL SAFETY
DISMANTLING / MAINTENANCE
6. Do not open the window while the luminaire is
operating, as this will reduce the effectiveness of
disinfection. We recommend ventilating the room
after operating hours of the device.
7. We recommend using the product in rooms with
unobstructed ventilation.
8. When switching on the device for the first time,
you may notice a burning smell from the UV-C
lamp for a short time. This odour is similar to the
odour you notice when using a sun bed, and will
disappear after a short time. This smell does not
pose a threat to the users of the device.
9. Once the device has been switched off, the lamp
will remain hot for approximately 10 minutes.
10. A small amount of visible blue light – which is a
reflected light, does not contain UVC radiation
and is safe for humans.
1. Remove the UV HALO together with the supplied
pipe clips from the packaging and position the UV
HALO with the pipe clips at the selected location so
that you can mark where the pipe clips should be
fitted onto the solid back wall (in case of wall-mounted
option). In case of installation in vertical or horizontal
position on the surface in the chosen place, please,
use vertical holder or horizontal support stand
accordingly for safety and comfortable usage.
counter will start counting backwards from the value it had when it was
switched off.
‘0000.’: The display will indicate 0000 when the 8,000 operating hours
of the lamp have expired. The actual time will be shown in the display,
alternating with four numbers. The UV-C lamp must now be replaced.
During maintenance work, or when dismantling
the device, always switch off the power supply by
removing the plug from the socket. The device must
be cleaned at least once a year. The special lamp
must be replaced after 8,000 operating hours at the
latest. Clean the aluminium interior with a soft cloth.