MANUAL OPERATION
The CyberQ will automatically revert to manual mode if a Wi-Fi signal is not
present. Therefore a cook in progress will not be interrupted by an Internet or
Wi-Fi problem.
MAIN SCREEN
>COOKTEMP: 275
O
F
FOOD 1: 32
O
F
FOOD 2: 180
O
F
FOOD 3: OPEN
To change Pit, Food, and Timer values, use UP/DOWN buttons to select line
and press Enter. Use the LEFT/RIGHT buttons to select the character and
UP/DOWN to change the values. Press Enter to save values.
Once Timer value is entered, the control will begin counting down. When the
countdown is finished, the action specified in
TIME- OUT
will be taken.
If Pit or Food probe is unplugged or damaged, it will show as “OPEN”.
When the Food Temp reaches its set point, the “FOOD DONE” message will
blink and the Alarm will sound. (Press any key to clear alarm)
Pit Set Temp: 32-475
O
F (0-270
O
C)
Food Set Temp
Fan Output %
FAN OUTPUT %
The output percent is not changeable. It is computed by the control.
The ‘*’ character is shown next to the output % value when the fan is blowing.
TIP:
During your cook if you notice the output percentage hovering around 80-100% for
a long time, you may be running out of charcoal. If you notice the output
% hanging around
10%
for a long time, and the temperature is oscillating, you may want to close the blower
damper adjustment slightly for better control.
SYSTEM SETUP SCREEN
>SYSTEM SETUP
SCROLLING: ON
BACKLIGHT: 50%
CONTRAST: 10%
UNITS: DEG F
To access System Setup Screen, hold both UP
and DOWN Buttons simultaneously for 3 seconds.
SCROLLING
Select automatic scrolling on the MAIN SCREEN. The default value is OFF.
BACKLIGHT
Adjustable from 0-100%.
Note that any adjustment may make the display unreadable; we suggest leaving it
at the default value of 50%.
CONTRAST
Adjustable from 0-100%.
Note that any adjustment may make the display unreadable; we suggest leaving it
at the default value of 10%.
UNITS
Select to use Deg. F (Default) or Deg. C.
ALARM BEEPS
Select OFF, 1, 2, 3, 4 and 5 alarm beeps.
KEY BEEPS
Select Key Beep ON/OFF when a key is pressed. The default value is ON.