Microseparator™ Coolant Systems Transport, Installation, & Initial Startup
M000005_A - V Twin Ultra Transport & Installation 5.2-EN TM
10/78
Danger, high voltage. Only qualified personnel
should service or access this portion of the
equipment.
Application instructions and other useful or
important information.
6
Operator Safety
All personnel responsible for operating the Microseparator™ should be
required to read these safety and cleaning procedures prior to operation.
Remember that centrifuges incorporate rotating components that should
be treated with the same caution as other rotating devices. Important
safety devices are built into each Microseparator™. Please carefully
observe the following safety notices.
1.
Only qualified electricians or duly trained personnel under the
instruction and supervision of a qualified electrician may do any work
on electrical equipment and systems.
2.
Always disconnect and lock out the power source before working on
or near the Microseparator™ rotor or drive motor.
3.
Motor controls should conform to instructions given in the installation
manual provided with the Microseparator™. Motor controllers must
be securely and adequately grounded according to NEC and local
codes of the specific area.
4.
Do not operate the Microseparator™ if severe vibration is observed.
Generally, incomplete rotor cleaning causes vibration. Do not operate
the Microseparator™ without a properly operating vibration switch.
5.
The Chip Separator must be operated with the cover on and a
properly working pneumatic limit switch.
6.
Do not place hands or feet in the Chip Separator, to avoid being
caught by the pneumatic arm.
7.
Practice good housekeeping and maintain a Safety Training and
Safety Equipment Operation/Maintenance Program for all employees.