background image

Supplied By www.heating spares.co  Tel. 0161 620 6677

Ebony Super

Baxi Heating Ltd.

page 8

Changing Components – Page 8

Before changing any components please read the
Important Information Section on page 2.

The following components can be removed as described below
after first removing the outer case. Turn off the gas and
withdraw the plug from the electrical supply before removing the
outercase.

ENSURE THAT THE FIRE IS COLD

GAS CONTROL TAP

 (Flame Failure Device)

(a)

Greasing the tap plug

 (Fig. 13). Pull off the plastic cap

and then the spark electrode lead from the piezo unit and
undo the two set screws and washers securing the niting
plate to the tap body.

Remove the piezo unit complete with the gas tap spindle
and spring. Now remove the plug and apply suitable
grease sparingly, e.g. Kluber N322B. (Excessive grease
may block the gasways). On re-assembling care must be
taken to ensure that both the plug and spring are in place.

(b)

To exchange the component

 (Fig. 11). (Disconnect the

gas supply and remove the fire from the fireplace.) Pull off
the plastic cap and disconnect the spark electrode lead
from the piezo unit. Disconnect the four tubes at the gas
tap. Disconnect the thermocouple from the gas tap.
Remove the 3 screws securing the gas tap bracket to the
inner case and remove the complete assembly. Remove
the locknut holding the gas tap to the bracket and remove
the gas tap.

On re-assembly ensure that the spark electrode lead is correctly
fitted and that the plastic cap is pushed on the piezo unit.
Ensure that the pilot filter supplied with the new tap is fitted.

GLASS FRONT PANEL

 (Fig. 10)

(a)

Ensure that the glass front panel is cold.

(b)

Slide the glass front panel retaining clamps sideways.

(c)

Lift the glass front panel bottom edge out of the locating
channel and carefully remove the glass front panel.

On re-assembly ensure that:

(a)

The glass front panel sealing rope is replaced if it is in
anyway damaged.

(b)

The glass front panel is replaced if it is in anyway
damaged or cracked.

NOTE:  This is a heat resistant glass front and must not be
replaced by ordinary glass.

COAL BED

 (Fig. 10)

Remove the glass front panel as described above.
Remove the coal bed by lifting it carefully away from the
locating pins.

CAUTION:  The coal bed is extremely fragile and must be
handled accordingly. Gloves should be worn and any
inhalation of the dust should be avoided. Keep the coals
away from children at all times. Please read the
Important Information Section on page 2.

On re-assembly ensure that the coal bed is correctly located
over the locating pins.

BURNER

 (Figs. 10,11 and 12)

(a)

Remove the glass front and coal bed as described above.

(b)

If fitted, remove the screw holding the pilot shield to the
burner rail.

(c)

Remove the screw holding the pilot assembly to it’s
bracket.

(d)

Disconnect the compression nuts from the injectors.

(e)

Remove the two screws securing the burner.

(f)

Ease the pilot assembly forwards and slide the burner out
above the glass locating channel.

(g)

Remove the injectors from the burner.

PILOT/THERMOCOUPLE/ELECTRODE
ASSEMBLY

 (Fig. 12)

NOTE: The thermocouple cannot be changed as an
individual component. The complete assembly must be
changed in the event of one or other component failure(s).

(a)

Disconnect the gas supply and remove the fire from the
fireplace.

(b)

Pull back the sleeve and disconnect the lead from the
electrode.

(c)

Undo the nut on the pilot feed pipe.

(d)

Remove the screw holding the assembly to the bracket.

(e)

Undo the thermocouple from the gas tap.

(f)

Remove the assembly from the fire.

(g)

On re-assembly, shape the thermocouple in a similar
manner to the original.

ELECTRO MAGNETIC UNIT

 (Fig. 11 and 13)

(a)

Remove the gas tap as explained in Gas Control Tap
section (b).

(b)

Remove the electro magnet retaining nut and withdraw the
electro magnet unit.

PIEZO UNIT

 (Fig. 13)

(a)

Pull off the plastic cap and disconnect the spark electrode
lead from the piezo unit.

(b)

Undo the tabs on the rear of the piezo unit and remove.

(c)

Replace the piezo unit twisting the tabs to retain it firmly in
position. Re-connect the spark electrode lead and re-fit the
plastic cap.

RESISTOR

(a)

Check that the mains lead is disconnected.

(b)

Remove the screw securing the light bulb cover and lift
upwards.

(c)

Remove the clip securing the resistor to the cover and
disconnect the 2 wires.

(d)

Replace the Resistor and reassemble in reverse order.

LIGHT SWITCH

Pull off the two flag terminals from the switch noting their
relative positions. Press together the retaining arms on the rear
of the switch and remove from the bezel. Replace the switch
and terminals.

Содержание EBONY SUPER

Страница 1: ...heating spares co Tel 0161 620 6677 Page 1 Please leave these Instructions with the User Baxi Ebony Super Gas Fire Comp No 236202 Issue 4 10 99 Installation and Servicing Instructions Baxi Ebony Super G C No 32 077 37 ...

Страница 2: ...ndling these articles to ensure the release of dust or fibres is kept to a minimum To ensure that the release of fibres from these articles is kept to a minimum during installation and servicing it is recommended that a H E P A filtered vacuum is used to remove any dust soot or other debris accumulated in and around the appliance This should be performed before and after working on the installatio...

Страница 3: ...CAL CONNECTION THIS APPLIANCE MUST BE EARTHED ALL EXTERNAL WIRING BETWEEN THE APPLIANCE AND THE ELECTRICAL SUPPLY SHALL COMPLY WITH CURRENT I E E REGULATIONS The mains lead has the following specifications 16 0 2mm 3 core PVC covered PVC insulated wire to BS 6500 IMPORTANT Mains lead wires Green and yellow Earth Blue Neutral Brown Live FOR THE MAINS PLUG USE A 3AMP FUSE The appliance is supplied w...

Страница 4: ...attention DO NOT FIT THE FIRE SEEK EXPERT ADVICE HEARTH FIXING Fireplace or Surround a Fit the fire backing plate to the fire using the M5 x 8mm thread forming screws provided The backing plate may be screwed to the wall for extra support if necessary Fig 6 b Position the fire minus the outer case against the closure plate and determine the position of the gas connection c Adjust the feet to level...

Страница 5: ... position and wait for 3 minutes before attempting to light the pilot again d Push in the control knob and turn fully anti clockwise Check that the ignition is satisfactory e Check the fire pressure with the control knob turned fully anti clockwise The pressure should be 14 1mbar 1 0mbar 5 6 in wg 0 4 in wg No adjustment is provided on the fire Turn the control knob to the OFF position Remove the ...

Страница 6: ...ve the outer case for access to all controls a Pull off the control knob b Remove the cover panel under the front of the fire by grasping it firmly by its side edges and pulling forwards c Remove the two case securing screws Fig 7 d Lift the case away from the heat exchanger 2 Remove the glass front panel Fig 10 a Ensure that the glass front panel is cold b Slide the glass front panel retaining cl...

Страница 7: ...Supplied By www heating spares co Tel 0161 620 6677 Ebony Super Baxi Heating Ltd page 7 Fit the Outer Case Page 7 ...

Страница 8: ...fting it carefully away from the locating pins CAUTION The coal bed is extremely fragile and must be handled accordingly Gloves should be worn and any inhalation of the dust should be avoided Keep the coals away from children at all times Please read the Important Information Section on page 2 On re assembly ensure that the coal bed is correctly located over the locating pins BURNER Figs 10 11 and...

Страница 9: ... Glass Frame Assembly 155 758 040955 C Knob Gas Tap Control 156 431 234551 D Flame Failure Device Gas Tap E05 653 242512 E Piezo Unit Vernitron 66111 393 734 042941 F Electro Magnet Unit E01 617 239413 G Injector F11 Cat 18 230 381 879 092133 H Burner Aeromatic Baxi Special 155 949 043210 I Oxy pilot Assembly 350mm SIT OP 9402 378 914 236204 J Lead Electrode 378 915 236199 K Coal Bed 156 429 23514...

Страница 10: ...Supplied By www heating spares co Tel 0161 620 6677 Ebony Super Baxi Heating Ltd Page 10 Fault Finding Chart Page 10 11 BAXI EBONY SUPER Gas Type G20 Natural Gas Click here for Helplines ...

Отзывы: