19
Operation
2.7.6
Current boiler output
The current boiler output is displayed in %. The boiler output (modulation
mode) can be set from 30 % to 100 % – Fig. 44.
Fig. 44
Current
boiler output
Back
70
%
2.7.4
Flue gas temperature
If a flue gas temperature sensor (accessory) is connected, this function displays
the current flue gas temperature – Fig. 42.
Fig. 42
Flue gas temperature
Back
114
°C
2.7.3
Pellet consumption total
The total amount of pellets consumed is displayed in tonnes – Fig. 41.
Note:
The „Pellet consumption total“ is a calculated value and can differ from
the actual value by ±15%.
Fig. 41
Pellet consumption
total
Back
1.30
t
2.7.5
Boiler temperature setpoint
The display indicates the boiler temperature setpoint as calculated by the con-
trol system. This setpoint is used to control the burner – Fig. 43.
Fig. 43
Boiler temperature
setpoint
Back
63
°C
The flue gas temperature is measured directly on the flue outlet. It may
therefore deviate from a standard measurement.
2.7.7
Display module software version
The current software version of the display module (InfoWIN) is displayed –
Fig. 45.
Fig. 45
Software version -
display module
Back
4.00
2.7.8
Firing automate software version
The current software version of the firing automate (main PCB) is displayed –
Fig. 46.
Fig. 46
Software version
firing automate
Back
4.10
2.7.9
Boiler model
The boiler model of the FireWIN is displayed – Fig. 47.
Fig. 47
Boiler model
Pellet boiler 120K
Boiler 0
Back