Commissioning the Fire

1. Remove the four radiants from their packing. Fit them 
by inserting their upper edge into the heat exchanger 
and then lowering them on to the burner rail. The lower
front edge should be flush against the radiant support rail.

2. Remove the pressure test point sealing screw and
connect a pressure gauge (Fig.5).

3. Turn on the gas service tap (at present supplying gas
to the boiler only) fully anti-clockwise. The service tap is
now supplying both the boiler and the fire (Fig.4).

4. Purge according to in GB BS 6891 and in IE the
current edition of I.S. 813 “Domestic Gas Installations”.

5. To light the fire - fit the fire control knob if not fitted and
ensure that it is fully clockwise. Push in and turn anti-
clockwise slowly to the positive stop to operate the igniter.
Repeat until the pilot and burner light. The burner flame
will be visible in the two centre radiants. Continue to hold
in the control knob for a further 15 seconds. Release
slowly and the pilot and burner should stay alight. If the
pilot and burner do not stay alight turn the control knob to
the OFF position fully clockwise and repeat.

6. Check that the fire burner crosslights smoothly by
pushing in the knob and turning fully anti-clockwise. Test
for gas soundness with leak detection fluid.

7. Check the fire pressure with the control knob in the
fully anti-clockwise position.The pressure should be
17.2mbar + 1.0mbar (6.9 in. wg. + 0.4 in. wg.).

8. Turn the control knob clockwise to the OFF position.
Remove the pressure gauge and refit the pressure test
point sealing screw, ensuring a gas tight seal.

9. Test for clearance of flue products as follows:

(a) Ensure that all doors and windows are closed.

IMPORTANT NOTE: If there is a ceiling or 
extractor fan in the room or adjoining room 
then the spillage test must be performed with 
the fan turned on and any interconnecting 
doors between the fan and the appliance 
left open.

(b) Light the fire and turn to position 4.
(c) After running for 5 minutes take a lighted smoke 

match and insert it into the smoke tube at the left 
hand side of the fire leaving 3mm of the match 
below the tube (Fig.6). No smoke emerging from 
the side hole indicates clearance.

Smoke emerging from the side hole indicates 
spillage and the test must be repeated after a 
further 5 minutes. 

If the fire does not clear its 

products, further investigation must be carried out.

After a further 5 minutes with both the boiler and 
the fire alight, insert a smoke match into the 
boiler down draught diverter. Ensure that most of 
the smoke is drawn into the flue (Fig.7).
If the boiler does not clear its products, further 
investigation must be carried out.

10.Fit the case as follows:

(a) Remove the control knob. (PW5 Deluxe only)
(b) Lift the outercase over the heat exchanger and 

locate the two 'vee' notches in the top of the case 
into the 'vee' notches at the top of the inner case 
(Fig.5).

(c) Secure the outercase to the inner case using the 

two securing screws provided (Fig.5).

12.Hand the user the User’s Instructions, explain the
operation of the boiler and fire and leave the unit set to
suit their requirements.

13.Leave these instructions with the user or adjacent to
the gas meter.

Location "Vee" Notches

Backing Plate

N

o

8 x 

3

/

8

in Screw

Pressure Test Point Sealing Screw

Fire Control Tap

Adjusting Feet (2 off)

Outercase Securing Screws (2 off)

Fig.5
PW5 Deluxe

Fig.5
C5 - C5W

Location "Vee" Notches

Backing Plate

Pressure Test Point
Sealing Screw

Fire Control
Tap

Adjusting Feet (2 off)

Outercase Securing Screws (2 off)

M5 x 8mm Screw

M5 x 8mm Screw

Clip

Clip

Содержание Bermuda PW5 C5

Страница 1: ... these Instructions safe Should you move house please hand them over to the next occupier Baxi Bermuda PW5 Deluxe C5 C5W Fireside Gas Central Heating Unit Installation and Servicing Instructions PW5 Deluxe C5W C5 ...

Страница 2: ...lowing boilers Baxi Bermuda 45 4 M G C No 44 077 71 Baxi Bermuda 45 4 E G C No 44 077 73 Baxi Bermuda 57 4 M G C No 44 077 72 Baxi Bermuda 57 4 E G C No 44 077 74 Baxi Bermuda 51 5 G C No 44 075 06 Baxi is a BS EN ISO 9001 Accredited Company Renewal Baxi Bermuda PW5 Deluxe Renewal G C No 37 075 10A Baxi Bermuda C5 Renewal G C No 37 075 07A Baxi Bermuda C5W Oak Renewal G C No 37 075 08A Baxi Bermud...

Страница 3: ...es for domestic purposes BS 5449 Part 1 Forced circulation hot water systems IMPORTANT The addition of anything that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty In GB this could also infringe the GAS SAFETY Installation and Use REGULATIONS Safe Installation The appliance is su...

Страница 4: ...UCTION This unit is the gas fire section of the Bermuda PW5 Deluxe C5 C5W central heating boiler and gas fire The heat input is 4 67kW 15 900 Btu h and the fire is available for use with Gas Type G20 Natural Gas at 20mbar or Gas Type G31 Propane C5 C5W Mahogany only The fire is controlled by a knob positioned on the right hand side of the case PW5 Deluxe models or on the top right hand side C5 C5W...

Страница 5: ...ler Push the fire backwards until the backing plate touches the finished wall face Adjust the feet to level the fire Fig 5 3 Mark the position of the most suitable pair of securing holes in the fire backing plate Fig 5 and remove the fire Drill and plug the wall with suitable plugs Replace the fire and secure to the wall with suitable fixing screws 4 Connect the gas supply pipe to the fire inlet c...

Страница 6: ...ndows are closed IMPORTANT NOTE If there is a ceiling or extractor fan in the room or adjoining room then the spillage test must be performed with the fan turned on and any interconnecting doors between the fan and the appliance left open b Light the fire and turn to position 4 c After running for 5 minutes take a lighted smoke match and insert it into the smoke tube at the left hand side of the f...

Страница 7: ...ndow Grey Push Button Target Aeration Hole Spark Electrode Spark Gap 3 0mm 4 0mm Service Tap Electronic Controls Boiler 45 4E 57 4E Fig 8 Outer Case Clearances PW5 Deluxe Fig 8 Outer Case Clearances C5 C5W C5W Not Shown Manual Controls Boiler 45 4M 57 4M Thermostat Knob Service Tap Fig 9 The Controls PW5 DELUXE Fig 9 The Controls C5 C5W Fig 10 Spark Gap Pilot Indicator Light Boiler Lockout Light L...

Страница 8: ...e Undo the injectors from the burner and clean carefully Do NOT use a pin or wire Using a soft brush remove any dirt or deposits from the burner and ensure that the ports are free from obstruction Clean any debris from the A S D assembly Do NOT use a pin or wire 8 Check that the spark gap is as in Fig 10 9 Replace the parts in reverse order of dismantling Make sure that the glass fibre sleeve is c...

Страница 9: ...sembly must be replaced in the event of one or other component failure s Only use a Genuine Baxi Spare Part Release the thermocouple and pilot feed pipe from the gas tap connection points Undo the pilot feed pipe nuts at each end and remove the pipe Undo the thermocouple nut from the tap Pull the electrode lead off it s terminal on the igniter and withdraw the lead and sleeve through the grommets ...

Страница 10: ...ilter Rectify flue YES Replace piezo igniter Check electrode lead insulation Is there a strong spark at the electrode Consult Gas Supplier Turn on gas supply Is gas supply turned on Is supply pressure correct 20mb working NO YES NO YES YES NO Has new pilot filter been fitted YES NO Is spark gap 3 to 4mm Adjust spark gap NO YES Is pilot burner clean Is flue blocked causing A S D to operate Change p...

Страница 11: ...ple output within limits Is meter pressure correct YES NO NO YES YES NO Pipe restricted or undersized Is supply pressure correct NO YES NO YES NO YES YES NO YES Are gas cocks fully open Is thermocouple tip sound NO YES Is flue blocked causing A S D to operate YES NO Open gas cocks Clean thermocouple tip Change pilot assembly Make good the connection Rectify flue Is pilot flame stable and approx 40...

Страница 12: ...ectrode E00 110 237840 H Arrester Lint 156 375 042779 J Radiant E00 129 237851 K Pilot Filter 205 723 082412 Key No Description G C Manufact rs No Part No A Dressguard 155 693 043036 B Knob Gas Tap Control 156 317 232705 Ca Tap Fire Control Piezo Unit E00 115 249763 D Injector C06 E00 131 238270 E Burner E00 116 237854 F Pilot ASD Assembly E00 113 238037 G Lead Electrode 280mm E00 117 250022 H Arr...

Страница 13: ... boiler hood and lift away Remove and discard the fire supply pipe from the service gas tap Disconnect and discard any electrical wiring between the boiler input terminal and the fire If the fire is wall mounted remove and discard the existing support frame Bermuda 401 only retain the two support brackets These will be needed in wall mounting the renewal fire If the fire is hearth mounted ensure t...

Страница 14: ... brackets from the previous plate must be fitted before the fire support plate can be fixed in place Push the support plate backwards until it touches the surround or wall face and tighten the screws to lock it in position BERMUDA 45 3 57 3 45 4 57 4 51 5 Take the fire support plate from the fire unit packaging and loosely attach it above the boiler base protruding from the fireplace opening using...

Страница 15: ...e CO7 37 0mbar 14 8 in wg Heat Input Gross Gas Group Injector Marking Supply Pressure The following spare components differ from Natural Gas models Description G C No Manufact rs Part No Injector Fire CO7 E00 130 238274 Pilot ASD Assy E00 114 238038 Pilot Shield Bracket Outercase Bermuda C5 Propane G C No 37 077 74 Bermuda C5W Mahogany Propane G C No 37 075 17 Pilot Shield Brackets Before fitting ...

Страница 16: ...Comp No 237650 Iss 11 1 03 B A X I P O T T E R T O N Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN After Sales Service 08706 096 096 Technical Enquiries 08706 049 049 www baxi co uk ...

Отзывы: