Additional Installation Instructions
PW5 Deluxe Renewal
G.C.N
o
37 075 10A
C5W Renewal (Oak)
G.C.N
o
37 075 08A
C5 Renewal
G.C.N
o
37 077 07A
The kit supplied with Renewal appliances provides all the
necessary components to fit a Baxi Bermuda firefront to
the following Bermuda Boilers.
The Renewal Fires may be used with the following
Boilers:
Bermuda 401
G.C.N
o
44 077 49
Bermuda 552
G.C.N
o
44 077 50
Bermuda 45/3 M
G.C.N
o
44 077 61
Bermuda 45/3 E
G.C.N
o
44 077 60
Bermuda 57/3 M
G.C.N
o
44 077 63
Bermuda 57/3 E
G.C.N
o
44 077 62
Bermuda 45/4 M
G.C.N
o
44 077 71
Bermuda 45/4 E
G.C.N
o
44 077 73
Bermuda 57/4 M
G.C.N
o
44 077 72
Bermuda 57/4 E
G.C.N
o
44 077 74
Bermuda 51/5
G.C.N
o
44 075 06
Existing Fire
REMOVING THE EXISTING FIRE
Isolate the gas and electrical supply, including any
permanent live, to the combined appliance.
Remove the controls cover panel from the front of the fire.
Remove the tap control knob. Disconnect the electrical
socket from the fire plug if fitted. Remove the screws
securing the outercase to the innercase. Lift off the
outercase.
Turn the gas service tap to the "Boiler only" position by
turning
1
/
4
turn clockwise.
Remove the radiants if fitted.
Disconnect the supply pipe at the fire inlet.
Remove any screws securing the fire to the wall. Pull the
fire forward until the flue spigot is clear of the boiler hood
and lift away.
Remove and discard the fire supply pipe from the service
gas tap. Disconnect and discard any electrical wiring
between the boiler input terminal and the fire.
If the fire is wall mounted remove and discard the existing
support frame.(Bermuda 401 only) retain the two support
brackets. These will be needed in wall mounting the
renewal fire.
If the fire is hearth mounted ensure that the base of the
builders opening and the front hearth are at the same
level.
Refer to "Site Requirements" (page 4) and prepare the
wall surface to the dimensions described.
Adhesive Foil Label
Renewal Firefront
401 & 552
Check the data badge on the back boiler. If the boiler
internal wiring is not depicted, take the foil label from
the kit and attach it below the data badge on the
boiler front door.
BERMUDA 45/3, 57/3, 45/4, 57/4 & 51/5
BERMUDA 401 & 552
Extension Plate
Bermuda 57/3 Illustrated
If a radiant firefront has not been installed previously
it will be necessary to fit the extension plate to the
boiler controls heat shield.
It is important that the existing installation is correct and
that the flue is performing satisfactorily. Any remedial
work necessary should be completed before the new
appliance is commissioned and the boiler should be
serviced before firefront is installed.
WARNING: Renewal firefronts are fitted with an
Atmospheric Sensing Device (A.S.D.). If they are
installed in conjunction with a boiler NOT fitted with
an A.S.D. (i.e. 401, 552, 45/3 & 57/3), under adverse
flue conditions the boiler WILL NOT shut down.