page 5
Fitting the Fire
Bend the central flap of the backing plate and the two
securing brackets as shown in the diagram.
Fit the fire backing plate to the fire using the M5 x 8mm
thread forming screws provided (Fig.5).
Fit the extension panel supplied with the fire to the boiler
controls heat shield using two of the No. 8 x
3
/
8
in. self
tapping screws (Fig.4).
IMPORTANT: The extension panel MUST be fitted.
HEARTH FIXING
1. Locate the fire spigot into the draught diverter on the
boiler. Push the fire backwards until the backing plate
touches the surround or finished wall face. Adjust the feet
to level the fire (Fig.5).
2. Mark the position of the most suitable pair of securing
holes in the fire backing plate (Fig.5) and remove the fire.
Drill and plug the wall with suitable plugs. Replace the fire
and secure to the wall with suitable fixing screws.
3. Connect the supply pipe to the fire inlet connection.
WALL FIXING
1. Slide the fire support plate over the overhanging boiler
base (Fig.4). Using the screws provided, loosely attach
the plate using the slots at each side.
2. On electronic control boilers it will be necessary to
disconnect the input plug from the controls. Push the
support plate backwards until it touches the wall surface
and tighten the screws to lock the frame in position.
Locate the fire spigot into the draught diverter on the
boiler. Push the fire backwards until the backing plate
touches the finished wall face. Adjust the feet to level the
fire (Fig 5).
3. Mark the position of the most suitable pair of securing
holes in the fire backing plate (Fig.5) and remove the fire.
Drill and plug the wall with suitable plugs. Replace the fire
and secure to the wall with suitable fixing screws .
4. Connect the gas supply pipe to the fire inlet connection.
Surround Face or
Finished Wall Face
Front "V" Mark
Gas Service Tap
D
560mm
(22in)
406-584mm
(16-23in)
PW5 991mm Min.
C5 & C5W 860mm Min.
PW5 991mm Min.
C5 & C5W 860mm Min.
If the opening is being purposely prepared the maximum dimensions are
strongly recommended
Fig. 1 Fireplace Opening
560mm
(22in)
406-584mm
(16-23in)
Fig. 2 Wall Fixing
Maximum
dimensions are
strongly
recommended
Fig. 3 Gas Supply Pipe
Fireplace
Opening
Fireplace
Opening
Skirting Board
Hearth
Level
100-125mm
(4-5in)
Fig. 4 Wall Fixing - Support Plate
Fire Support
Plate
Controls Heat
Shield
Gas Service
Tap
Appliance Details
B
ERMUDA
PW5 Deluxe
Height - 637mm (to hearth)
(see page 7
Width - 832mm
for clearances)
Depth - 206mm
B
ERMUDA
C5/C5W
Height - C5 639mm (to hearth)
C5W 654mm (to hearth)
(see page 7
Width - 720mm
for clearances)
Depth - 201mm
H
EAT
I
NPUT
(
GROSS
)
4.67kW (15,900 Btu/h)
G
AS
G
ROUP
G20 (Natural Gas)
I
NJECTOR
S
IZE
170S (PW5Deluxe)
C06 (C5 & C5W)
S
ETTING
P
RESSURE
(Cold) 17.2+1 mbar (6.9+ 0.4 in wg)
T
HERMOCOUPLE
O
UTPUT
7.5 - 13mV
P
ILOT
A
SSY
21100/165
H
EAT
I
NPUT
(
GROSS
)
210W (715 Btu/h)
Extension
Panel
675mm Min.
(26
1
/
2
in) C5W
660mm Min.
(26in) PW5 &C5
675mm Min.
(26
1
/
2
in) C5W
660mm Min.
(26in) PW5 &C5
Backing Plate