4.3.2
Position of the appliance
Caution
Install the appliance in a frost-free location.
1. Position the appliance as close as possible to the draw-off points in
order to minimise energy losses through the pipes.
2. Place the appliance on a base frame to facilitate cleaning of the area.
3. Install the appliance on a solid, stable structure able to bear its weight.
4.3.3
Main dimensions
AS 300–2E BC
Fig.4
B
C
D
A
E
F
Ø G
55
°
K
83.5
83.5
7
1
4
3
6
9
MW-5000825-2
8
5
2
1
Domestic hot water outlet G1"
2
Domestic hot water recirculation G3/4"
3
Exchanger inlet G1"
4
Domestic hot water sensor
5
Exchanger outlet G1"
6
Domestic cold water inlet and drain opening G1"
7
Solar exchanger inlet G3/4"
8
Solar exchanger outlet G3/4"
9
Solar sensor position
Caution
G: Cylindrical threading, sealed by sheet gasket
Tab.3
AS 300–2E BC
A
70.5
B
602
C
992
D
1319.5
4 Installation
14
AS 300–2E BC
7724479 - v03 - 07102019
Содержание AS 300-2E BC
Страница 25: ...No Date Checks made Remarks By Signature 6 Maintenance 7724479 v03 07102019 AS 300 2E BC 25 ...
Страница 28: ...8 Appendix 28 AS 300 2E BC 7724479 v03 07102019 ...
Страница 29: ...8 Appendix 7724479 v03 07102019 AS 300 2E BC 29 ...
Страница 30: ...8 Appendix 30 AS 300 2E BC 7724479 v03 07102019 ...
Страница 32: ...7724479 v03 07102019 7724479 001 03 ...