8.0 Annual Servicing
21
8.7
Cleaning the Heat Exchanger
1. Remove the top and the centre baffles from
the heat exchanger, noting their orientation
(Fig. 43).
2. Remove the side and rear insulation pieces by
undoing the screws retaining the support
brackets and sliding the rear bracket to the left
and both side brackets forward (Fig. 44, 45,46 &
47).
3. Each bracket may then be removed along with
the insulation.
4. Clean between the heat exchanger fins and
flueways with suitable brushes and remove any
deposits from the combustion box base tray.
5. Clean away any lint or other deposits from the
boiler hood and builders opening.
6. Reassemble the insulation in reverse order
and refit the baffles.
7. Reassemble the appliance in reverse order,
re-greasing the thermostat phial if required.
8. Re-commission the appliance and check for
gas soundness.
9. Complete the relevant section of the
“
Benchmark
”
Installation, Commissioning and
Service Record Log Book and hand it back to
the user.
Slide Rear Insulation
Bracket Left Before
Pulling Forward
Heat Exchanger
Baffles
Undo the Retaining
Screws on the Support
Brackets
Remove each Bracket
and Insulation
Fig. 43
Fig. 44
Fig. 45
Fig. 46
Fig. 47