6.7
Water Connections
1. The boiler has one return and two flow
tappings, Rc1 (1in BSP). The flows are the two
upper tappings. The return is the lower position
tapping and is marked RETURN. It is essential
the flow and return pipes are connected to the
correct tappings.
6.8
Fully Pumped Systems
(Fig. 16)
1. A 1in x 22mm threaded adaptor, compression
nut and olive are provided in the kit for the return
connection.
2. The 1in x 22mm threaded adaptor provided
must be fitted to the lower tapping marked
RETURN. Connect the pumped return into the
adaptor using the nut and olive.
3. Fit a 1in x 22mm threaded adaptor into one of
the higher tapping positions marked FLOW and
connect the pumped flow into the adaptor.
4. Fit a 1in plug to the remaining connection.
6. Follow the instructions under
‘
System Details
’
as regards the vent pipe and cold feed.
Pumped Flow Use
Either Connection
Pumped Return
Plug Remaining
Connection
Fig. 16