5 Before installation
32
Combi 2
Fig.20
Flexible flue trims
5.4.8
Flue/chimney trim
The flexible flue trims supplied can be fitted on the outer and inner faces of
the wall of installation.
Fig.21
Terminal guard
Fig.22
Flue deflector
PN-0000390
PN-0000460
PN-0000461
5.4.9
Terminal guard
1
ENSURE THAT NO PART OF THE WHITE OUTER
CHIMNEY DUCT IS VISIBLE.
When codes of practice dictate the use of terminal guards Multifit accesso-
ry part no. 720627901 can be used
Important
This guard is not compatible with Flue Deflector referred to below.
There must be a clearance of at least 50mm between any part of the
terminal and the guard.
When ordering a terminal guard, quote the appliance name and model
number.
The flue terminal guard should be positioned centrally over the terminal
and fixed as illustrated.
5.4.10 Flue/chimney deflector
1
Flue deflector
Push the flue deflector over the terminal end. It may point upwards as
shown, or up to 45° either way from vertical. Secure the deflector to the
terminal with screws provided.
5.4.11 Flue/chimney accessories
See
For full details of Flue Accessories (elbows, extensions, clamps
etc.) refer to the Flue Installation Guide supplied in the literature
pack.
Warning
SUPPORT
- All flue systems MUST be securely supported at a
MINIMUM of once every metre & every change of direction. It is
recommended that every straight piece is supported irrespective
of length. Additional supports are available as accessories.
VOIDS
- Consideration must be given to flue systems in voids and
the provision of adequate access for subsequent periodic visual
inspection.
1